Changing the cutters:
• Switch off the unit.
• Unplug the unit.
• Allow the cutter to cool.
• Remove the work table (Fig. 8).
• Remove the protective cap (Fig. 9).
The protective cap is more easily
removed by pressing it together
at the flat surfaces of the clamp-
ing ring (Fig. 9).
• Loosen the clamping ring with the Allen
key supplied (Fig. 10).
The Allen key is kept in a holder
under the work table.
• Remove the cutter.
• Insert the new cutter fully into the clamp-
ing ring.
• Tighten the clamping ring with the Allen
key (Fig. 10).
Ensure that the clamping ring
has been adequately tightened.
• Replace the protective cap.
• Place the Allen key in the holder.
• Replace the work table.

3. Cleaning / Servicing

Switch off and unplug the unit
before cleaning or servicing it.

3.1 Cleaning the housing

Never clean the unit under
running water or immerse it in
water.
Do not steam clean the unit.
Risk of injury!
Cover sharp cutters if necessary.
Do NOT use cleaning agents that
are caustic or abrasive or that
contain solvent.
EN
• Switch off the unit.
• Unplug the unit.
• Wipe the housing with a damp cloth.
• Remove the work table (Fig. 8).
• Vacuum out the dust receptacle and wipe
with a damp cloth.
• Dry the unit with a soft, clean cloth.

3.2 Cleaning the work table

• Remove the work table (Fig. 8).
• Clean the work table, e.g. steam clean.
• Dry the work table and replace it on the
unit.

3.3 Changing the fuse

3.3.1 M
illo
Before replacing the fuse, dis-
connect the unit from the mains
power supply by unplugging the
power cord from the wall outlet.
Never use fuses with a higher
rating.
• Unplug the unit.
• Place the unit on its side.
• Open the fuse holder (G, Fig. 5) and
change the fuse.
3.3.2 M
illo pro
• Unplug the unit.
• Press in the safety cut-out (F, Fig. 2) on
the side of the unit.

4. Replacement parts

You can find components subject to wear
and the spare parts on the spare part list
in the internet at www.renfert.com/p918.
The components excluded from the
warranty (such as consumables or parts
subject to wear and tear) are marked on
the spare part list.
Serial number and date of manufacturing
are shown on the type plate of the unit.
- 4 -