WARNING
• WARNING. All cleaning jobs must only be performed after carrying out the operations described in the
"STOP" paragraph, meaning without any moving parts, no pipe full of liquid under pressure and
only after complete cooling. In particular, always remember to disconnect the power supply.
• Any cleaning jobs must be performed in conditions of total stability.
• To clean, do not use thinners or solvents.
• Any anti-freeze liquid used to protect the pump from freezing must be suitably disposed of and not
discarded in the environment.
CAUTION
• Refer to the use and maintenance manual for the machine that incorporates the pump. After use,
complete a cleaning cycle, making the pump take up clean water. Never store the pump with
pumped liquid inside it.
• The pump is not frost proof.
In order to prevent the formation of ice inside the pump in cold areas, we recommend making the
pump take up a motor vehicle grade anti-freeze before starting the "storage" procedures (diluted
as instructed for the minimum temperature that the pump will be exposed to) and then drain it
completely, making it operate for a few minutes without taking up any liquid.
In case of ice, do not operate the pump.
Failure to abide by these instructions can cause serious damage to the pump.
• During storage, protect the pump from dirt and dust.
WARNING
• Follow the maintenance instructions contained in the manual of the machine in which the pump
is integrated.
• All maintenance jobs must only be performed after carrying out the operations described in the "STOP"
paragraph, meaning without any moving parts, no pipe full of liquid under pressure and only after
complete cooling.
In particular, always remember to disconnect the power supply.
• Any maintenance jobs must be performed in conditions of total stability.
• WARNING. To ensure the safety of the pump, only use original spare parts supplied by the Manufacturer
or approved by it.
Perform the routine maintenance jobs shown in the manual of the machine in which the pump
is integrated; unless otherwise indicated, in relation to the pump, remember the following.

MAINTENANCE SCHEDULE

After every use
Every 50 hours
(1)
Checks must be made more frequently if the pump operates where there are strong vibrations (crawler tractors,
28
combustion engines, etc.).
CLEANING AND DECOMMISSIONING
MAINTENANCE

ROUTINE MAINTENANCE

• Check oil level and conditions according to instructions in "PRELIMINARY
ACTIVITIES" paragraph.
• Check and if necessary clean the suction filter.
• Check the accumulator inflation pressure (when present).
• Check the integrity of the suction and delivery circuit.
• Check the fastening of the pump to the motor to which it is coupled and/or
to the structure of the machine in which it is integrated.
In the event of such fastening being precarious, do not use the machine
and contact a Skilled Technician