15 Spare Parts and Accessories

The silencers used can be replaced with AVENTICS material number R412010247. To ensure a
good hold, the silencer should be screwed in another 5–10° after the initial contact.

16 Technical Data

Safety relevant data
Service life parameter B
10
Fault exclusion
Sound pressure level
Overview of the achievable diagnostic coverage level (DC), categories and PL depending on
the safety function and product variant:
SF
Product variant
DC
1)
SF1
R422003980/–982
> 99%, both valves position
R422003729/–730
monitored
2)
SF2
R422003980/–982
> 99%, both valves
R422003729/–730
position monitored
1)
SF1: Safe exhaust
2)
SF2: Prevention of unexpected start-up
Proven component in terms of
The dual valve variants can be viewed as proven
ISO 13849-1
components in terms of ISO 13849-1 in the area of industrial
automation for the functions "safe exhaust" and "prevention
of unexpected start-up" under the following conditions, if
they are exclusively operated in accordance with all
information contained in these operating instructions,
especially in compliance with the performance limits and
ambient conditions stated in the technical data.
General data
Dimensions (length x width x height)
Weight
Working pressure min./max.
Control pressure min./max.
Ambient temperature min./max.
Storage temperature min./max.
Ambient operating conditions
Permissible medium
Max. particle size
Oil content of compressed air
The pressure dew point must be at least 15°C below the ambient and medium temperatures
and must not exceed 3°C.
The oil content of compressed air must remain constant during the life cycle.
O
Use only the approved oils from AVENTICS, see the AVENTICS online catalog, chapter
"Technical information".
Mounting orientation
Vibration resistance
Shock resistance
IP protection class
Switching times (at 6.3 bar)
On (1 -> 2)
Off (2 -> 3)
Nominal flow for pressurization
1 -> 2
Nominal flow for exhaust
2 -> 3
Electrical data
Max. positive test pulse
Max. negative test pulse
Relative humidity
Coil, CO1 series (1824210223)
Electrical connection
Power supply
Power consumption
Coil, CO1 series (1824210354)
Electrical connection
Power supply
Power consumption
Please ask AVENTICS for latest B
10
declaration.
W
Change of the output switching position of
a IS12-PD valve (without input signal)
94,8 dB(A) L
or 92 dB(C) L
p,A,peak
p,C,peak
(measured on a volume of 0.75 l at 6.3 bar)
Warning! This may irreversibly damage the
hearing. Always wear ear protectors during
operation.
Category max.
PL max.
4
4
160 mm x 152 mm x 160 mm
3700 g
1 to 10 bar external pilot
3 to 10 bar internal pilot
3 to 10 bar
0°C/+50°C
0°C/+50°C
Max. height above sea level: 1000 m
Compressed air in accordance
with ISO 8573-1 (7; 4; 4)
5 μm
3
0-5 mg/m
Any
±0.35 mm displacement at 10 Hz–60 Hz,
5 g acceleration at 60 Hz to 60 Hz
30 g with 18 ms duration
3 shocks each direction
IP65
20 ms
50 ms
1950 std l/min
3000 std l/min (including in error case)
1000 μs
700 μs
Max. 75% at 50°C
EN 175301-803, form A (without Zener
diodes)
24 V DC ± 10%
4.4 W
EN 61076-2-101, M12x1
24 V DC ± 10%
4.5 W
Electrical data
Sensor, ST4 series
Electrical connection
Min./max. power supply
Max. switching current
Vibration resistance
Shock resistance
Voltage drop U at I
max
Type of contact
Cable length
Sensor LED
Electrical safety
O
For further technical data, see the catalog pages in the AVENTICS online catalog (see
www.aventics.com/pneumatics-catalog).
e
e
M8 with knurled nuts
10/30 V DC
0.1 A
10–55 Hz, 1 mm
30 g/11 ms
≤2.5 V
Electronic PNP
0.3 m
Yes
Protection class III