4 TYPES AND SPECIFICATIONS

4.1 ABW COMPACT TYPES

4.1.1 ABW Compact

ABWC 16 DN 3 - 16 AZ1 F - C 0 2 2 0
Maximum current
08
800 A
Phase sequence
16
1,600 A
DN
p/ 1,600 A
Rated current
Number of poles
08
800 A
3
16
1,600 A
Version
F
Fixed
E
Withdrawable
FF
Fixed - Front
Protection unit
Standard unit
LSIG + current - electronics power supply 100~250 V ac/dc and measurement
AZ1
Optional units
000
LSIG + current - electronics power supply 100~250 V ac/dc and measurement
AZ6
LSIG + current - electronics power supply 24~60 V dc and measurement frequency
AZ2
LSIG + current - electronics power supply 24~60 V dc and measurement frequency
AZ7
LSI + earth leakage + current - electronics power supply 100~250 V ac/dc and
AF1
measurement frequency 60 Hz
LSI + earth leakage + current - electronics power supply 100~250 V ac/dc and
AF6
measurement frequency 50 Hz
LSI + earth leakage + current - electronics power supply 24~60 V dc and
AF2
measurement frequency 60 Hz
LSI + earth leakage + current - electronics power supply 24~60 V dc and
AF7
measurement frequency 50 Hz
LSIG + current + communication
AC1
measurement frequency 60 Hz
LSIG + current + communication
AC6
measurement frequency 50 Hz
LSIG + current + communication
AC2
measurement frequency 60 Hz
LSIG + current + communication
AC7
measurement frequency 50 Hz
LSIG + voltage + current + communication
PC1
100~250 V ac/dc and measurement frequency 60 Hz
LSIG + voltage + current + communication
PC6
100~250 V ac/dc and measurement frequency 50 Hz
LSIG + voltage + current + communication
PC2
and measurement frequency 60 Hz
LSIG + voltage + current + communication
PC7
and measurement frequency 50 Hz
Accessories supplied as optional items
Motorized operator
Undervoltage release
Condenser trip device
Key lock
Key interlock
Notes: 1) 2 circuit breakers are already considered for mechanical interlock M for the final configured material.
3 circuit breakers are already considered for mechanical interlock M3 for the final configured material.
2) For communication via Profibus network, it is necessary to use the ABW-CP accessory.
For communication via Modbus network, see the Communication section of this catalog.
- RST (N)
3P
Standard auxiliary contacts
C
4NO+4NC
Optional (withdrawable version)
D
4C position auxiliary contact
E
8C position auxiliary contact
frequency 60 Hz
No protection unit
frequency 50 Hz
60 Hz
50 Hz
2)
- electronics power supply 100~250 V ac/dc and
- electronics power supply 100~250 V ac/dc and
2)
- electronics power supply 24~60 V dc and
2)
- electronics power supply 24~60 V dc and
2)
- electronics power supply
2)
- electronics power supply
2)
2)
- electronics power supply 24~60 V dc
2)
- electronics power supply 24~60 V dc
Door frame
Transparent cover
Mechanical interlock
Door interlock
Position auxiliary contact
Motorized operator
Standard
0
No motor operator
Optional
1
100~130 V ac/dc
2
200~250 V ac/dc
3
24~30 V dc
Accessories supplied as standard for the entire range
Auxiliary contacts (4NO+4NC)
Alarm contacts
Opening coil 200~250 V ac/dc
Closing coil 200~250 V ac/dc
Operation counter
Position locking with padlock (padlock not included) - withdrawable version
Position indicator (Inserted /Test/ Withdrawn) - withdrawable version
ABWC Compact Air Circuit Breaker | 19
www.weg.net
Accessories
No accessories
B
ON/OFF button lock
K
Key lock
K2
Key interlock
Mechanical interlock for 2 circuit
M
breakers
1)
Mechanical interlock for 3 circuit
M3
breakers
1)
D
Door interlock
BK
B+K
B2
B+K2
BM
B+M
BD
B+D
KM
K+M
KD
K+D
CP
Profibus communication
CM
Modbus communication
Undervoltage release
Standard
0
No release
Optional
1
100~130 V ac/dc
2
200~250 V ac/dc
3
24~30 V dc
4
48~60 V ac/dc
5
380~480 V ac
6
200~250 V ac/dc with delay
7
100~130 V ac/dc with delay
8
48~60 V ac/dc with delay
9
380~480 V ac with delay
Standard opening coil
2
200~250 V ac/dc
Optional
0
No release
1
100~130 V ac/dc
3
24~30 V dc
4
48~60 V ac/dc
5
380~480 V ac
Standard closing coil
2
200~250 V ac/dc
Optional
0
No release
1
100~130 V ac/dc
3
24~30 V dc
4
48~60 V ac/dc
5
380~480 V dc