Reading the minimum volumetric
A gauge is mounted on the front of the de-
vice that shows the vacuum intensity.
(see chapter Description of the unit)
The table shows the maximum vacuum in-
tensity value. This value depends on the
unit performance and the suction hose
used.
ATTENTION
Suction loss
If the specified value is exceeded, the air
speed in the suction hose drops below
20 m/s.
Clean the bag filter when the value is
reached, or sooner.
If cleaning does not significantly lower the
value, change out the bag filter.
(see chapter Replacing the bag filter)
Hose diameter Value
DN 40
180 mbar (18 kPA)
DN 50
160 mbar (16 kPA)
 Clean the filter before or when the spec-
ified value is reached.

Emptying the collection container

See graphics page for illustrations
1. Switch the device off and disconnect it
from the power supply.
2. Clean the dust filter.
3. Push down the lever to lower the collec-
tion container.
Illustration F
4. Pull the collection container out of the
device.
Illustration G
5. Empty the collection container into the
waste container.
6. Dispose of or reuse the contents in ac-
cordance with applicable law.
7. Empty the collection container after
each use and otherwise as needed.
Note
Only move the collection container only on
its rollers. Do not use a crane, forklift or sim-
ilar means.
16
flow
Remove PE dust bag
See graphics page for illustrations
Illustration H
1. Disconnect the pressure equalisation
hose from the collection container.
2. Take the collection container out of the
device.
3. Remove the fastener from the PE dust
bag.
4. Close the PE dust bag using a cable tie
or adhesive tape.
5. Dispose of the dust bag in accordance
with statutory regulations.
6. Insert the new dust bag into the collec-
tion container.
7. Place the fastener inside.
Ensure that the PE dust bag is not dam-
aged.
8. Insert the collection container into the
device and connect the pressure equali-
sation hose.
Removing the suction head
See graphics page for illustration
1. Switch off the device and disconnect
from the power supply.
2. Open the suction head lock.
Illustration I
3. Remove the suction head and put it to
one side.

Finishing operation

1. Switch off the device using the On/Off
switch
2. Empty and clean the collection contain-
er.
3. Remove the accessories and clean and
dry them as necessary.
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during
transport and storage.
1. When transporting in vehicles, secure
the device against slipping and tipping
over according to the applicable guide-
lines.