SUPPLY
MAINS
1
When in the battery charger frontal panel is lighted the RED LED, is necessary to charge
the battery as follows:
A) Disconnect the start key (rif. pag. 14 "Instruments" n° 1).
B) Connect the cable (1) to the internal battery charger (5) and then connect it to the
supply mans with a socket type "SCHUKO" of 220V 10 A avoiding the use of electric
adaptors.
C) Verify on the GREEN LED (4) if the charge process start.
Disconnect the cable (1) from the supply mains to stop the charge process when the
battery charge is full.
The charge process is composed as follows:
The battery charger is active with the connections of the supply plug at the socket of
!
the socket of supply mains; in this stage the GREEN LED is lighted (4). During the
START-UP period the internal relay is open so the battery is disconnect from the
battery charger for more safety. Then there is the check of the battery voltage. The
internal relay close itself and start the charge process with a soft rise of the current
(soft-start) da zero ampere to the planed value.
The YELLOW LED (3) is lighted during the final period of the battery charge.
!
At the end of the battery charge the GREEN LED (4) is lighted.
!
Are shown the fallowing failure with the RED LED flashed
- Internal thermostat
- Time-out of the process
- Short circuit
During a failure period, the internal relay is open the battery is disconnect from the
battery charger for more safety.
In the case of the battery charger doesn't work verify the fuse (6) and change it if is fused.
W10 INOX
BATTERY CHARGE
INTERNAL BATTERY CHARGER FRONTAL PANEL
6
16
5
2
3
4
Fuse: F8A universal input
Do not remove the cover
Danger of electric shocks
UK16