4. MINIMUM TORQUE screen is displayed. MINIMUM TORQUE is value at which green progress lights,
audible alert and vibrator turn on. Initial MINIMUM TORQUE value is value from target torque screen.
MINIMUM TORQUE can be set to any value from TARGET TORQUE to tool minimum torque range by
pressing UP/DOWN buttons. Once desired minimum torque value has been set, press ENTER button.
5. MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above which
red progress lights turn on. Initial MAXIMUM TORQUE value will be MINIMIUM TORQUE value plus
4%. Maximum torque value can be set greater than TARGET TORQUE value to 10% above wrench
maximum range by pressing UP/DOWN buttons. Once desired maximum torque value has been set,
press ENTER button.
6. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP/DOWN buttons to increment/decrement batch count. Mode Count increments each time target
torque is reached if a batch count of zero is entered. Mode Count decrements if a non-zero batch
count is entered and resets to batch count value when count reaches zero. Once desired batch
count value has been set, press ENTER button.
7. PSET target screen is displayed labeled with next available PSET number from 01 to 10.
8. To enter additional torque presets, repeatedly press ENTER button until target torque screen is
displayed and repeat steps above.
STD
SLIM/SCR
ADDING AN ANGLE PRESET
1. From manual target angle screen, press and hold UNITS button for 3 seconds.
2. ADD PRESET confirmation screen is displayed. Highlight YES menu selection using UP/DOWN buttons
then press ENTER button. NO menu selection returns to main menu without adding a PSET.
3. MINIMUM ANGLE screen is displayed. MINIMUM ANGLE is value at which green progress lights, audi-
ble alert and vibrator turn on. Initial MINIMUM ANGLE value is value from target angle screen. MINIMUM
ANGLE can be set from 0 to 360º by pressing UP/DOWN buttons. Once desired minimum angle value
has been set, press ENTER button.
17