Note: All user configurable settings are stored in non-volatile memory and are retained while
power is off.
SHOW INFO
Show Info menu selection displays tool operational information.
1. From Settings menu, press ENTER button while SHOW INFO selection is highlighted.
2. SHOW INFO screen is displayed.
3. UP/DOWN buttons are used to scroll screen.
Operational Information:
CAL: Date of last tool calibration.
ISD: In-Service Date (remains blank until real-time-clock set).
TCF: Torque Calibration Factor.
ACF: Angle Calibration Factor.
VER: Software version.
OVR CNT: Overtorque Counter tracks how many times an over-torque event occurred on wrench
(torque >125% of full scale).
AZZ: Angle Z-Axis Zero Offset (only on SLIM wrenches).
AZX: Angle X-axis Zero Offset (only on SLIM wrenches).
AZO: Angle Zero Offset at full scale torque (only on SLIM wrenches).
TFS: Torque full scale value (only on SLIM wrenches).
Copyright.
TQZ: Torque Zero Offset.
ANZ: Angle Zero Offset (only on STD & SCR instruments).
AFS+: Angle Zero Offset at CW Torque Full Scale (only on SCR instrument).
AFS-: Angle Zero Offset at CCW Torque Full Scale (only on SCR instrument).
TFS+: CW Torque Full Scale (only on SCR instrument).
TFS-: CCW Torque Full Scale (only on SCR instrument).
4. Pressing ENTER button exits Show Info screen and returns to Settings menu.
STD
SETTING SLEEP TIME
This function will allow user to set interval tool enters power-down state following last applied torque
or button press.
1. From Settings menu, use UP/DOWN buttons to highlight SLEEP TIME selection then press
ENTER button.
2. SLEEP TIME screen is displayed.
3. Use UP/DOWN buttons to select sleep interval.
Selectable Intervals: 2 MIN (factory default); 5 MIN; 10 MIN; 30 MIN; 1 HR; 2 HR; 8 HR
4. Press ENTER button to accept selection and exit to Settings menu.
TAW AND TAS SERIES
ISD: In-Service Date (remains blank until real-time-clock set).
TCF: Torque Calibration Factor.
ACF: Angle Calibration Factor.
VER: Software version.
OVR CNT: Overtorque Counter tracks how many times an over-torque eve
(torque >125% of full scale).
AZZ: Angle Z-Axis Zero Offset (only on SLIM wrenches).
AZX: Angle X-axis Zero Offset (only on SLIM wrenches).
AZO: Angle Zero Offset at full scale torque (only on SLIM wrenches).
TFS: Torque full scale value (only on SLIM wrenches).
Copyright:
CAL: Calibration date of intrument
TQZ: Torque Zero Offset.
ANZ: Angle Zero Offset (only on SCR instrument).
AFS+: Angle Zero Offset at CW Torque Full Scale (only on SCR instrument)
AFS-: Angle Zero Offset at CCW Torque Full Scale (only on SCR instrument
TFS+: CW Torque Full Scale (only on SCR instrument).
TFS-: CCW Torque Full Scale (only on SCR instrument).
4. Pressing ENTER button exits Show Info screen and returns to Settings menu
SLIM/SCR
SLIM/SCR
SETTING SLEEP TIME
This function will allow user to set interval tool enters power-down state followin
or button press.
1. From Settings menu, use UP/DOWN buttons to highlight SLEEP TIME selec
ENTER button.
2. SLEEP TIME screen is displayed.
3. Use UP/DOWN buttons to select sleep interval.
Selectable Intervals: 2 MIN (factory default); 5 MIN; 10 MIN; 30 MIN; 1 HR; 2
4. Press ENTER button to accept selection and exit to Settings menu.
SLIM/SCR