Operating Conditions - Suunto DW141 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
4.2 Enriched Air Nitrox diving use
This device can be used with nitrox breathing gases (also known as oxy-nitrogen).
The maximum nitrox breathing gas oxygen concentration is 40%.
WARNING: Do not use nitrox gas mixtures if you do not have proper training.
Appropriate training courses about nitrox and oxygen diving are essential prior to
the use of this kind of equipment with oxygen content greater than 22%.
WARNING: In nitrox use, the maximum operating depth and exposure time are
dependent on the oxygen content of the gas.
WARNING: There is a danger when using nitrox that contaminants may give rise
to an oxygen ignition.
WARNING: The use of breathable air according to EN 12021 may contaminate
the diving apparatus.
NOTE: To minimize the risk of oxygen ignition, pressure vessel valve(s) should
always be opened slowly.
4.3 Oxygen calculations
The oxygen calculations are based on currently accepted exposure time limit
tables and principles.
By default in Air/Nitrox dive mode, CNS% and OTU values are not displayed until
they reach 80% of their recommended limits. When either value reaches 80%,
Suunto EON Steel notifies you and the value stays in the view.
• Audible alarm when pO
• Audible alarm when pO
WARNING: WHEN THE OXYGEN LIMIT FRACTION INDICATES THAT THE
MAXIMUM LIMIT IS REACHED, YOU MUST IMMEDIATELY TAKE ACTION TO
REDUCE OXYGEN EXPOSURE. Failure to take action to reduce oxygen exposure
after a CNS%/OTU warning is given can rapidly increase the risk of oxygen toxicity,
injury, or death.
NOTE: You can customize views to always show CNS% and OTU.

5 OPERATING CONDITIONS

• Altitude range: 0 to 3000 m (0 to 10000 ft) )above sea level
• Operating temperature: 0 °C to 40 °C (32 °F to 104 °F)
NOTE: Diving in freezing conditions may damage the dive computer. Make
sure the device is not getting frozen when wet.
• Storage temperature: -20 °C to +50 °C (-4 °F to +122 °F)
NOTE: Do not leave the dive computer in direct sunlight!
• Recommended charging temperature: 0 °C to +35 °C (32 °F to +95 °F)
• Maintenance cycle: 500 dives or two years, whichever comes first
WARNING: Do not expose the device to temperatures above or below the given
limits, otherwise it might get damaged or you might be exposed to safety risk.
6 HANDLING GUIDELINES AND MAINTENANCE
Handle Suunto EON Steel with care. The sensitive internal electronic components
may be damaged if the device is dropped or otherwise mishandled.
When traveling with this dive computer, ensure that it is packed securely in check-
value exceeds the preset limit (pO
2
value is < 0.18 (pO
2
2
low alarm)
2
high alarm)
9

Publicidad