Using rechargeable batteries
You can also operate this instrument using rechargeable batteries.
Please use only type «NiMH» reusable batteries!
The batteries must be removed and recharged, if the battery
symbol (battery flat) appears! They must not remain inside
the instrument, as they may become damaged (total
discharge as a result of low use of the instrument, even
when switched off).
Always remove the rechargeable batteries, if you do not
intend to use the instrument for a week or more!
The batteries can NOT be charged in the blood pressure
monitor! Recharge these batteries in an external charger
and observe the information regarding charging, care and
durability!
10. Using a Mains Adapter
7.
You can operate this instrument using the Microlife mains adapter
You can operate this instrument using the aponorm
(DC 6V, 600mA).
adapter (DC 6V, 600mA).
Use only the Microlife mains adapter available as an orig-
Use only the aponorm
inal accessory appropriate for your supply voltage, e.g. the
lable as an original accessory appropriate for your supply
«Microlife 230V adapter».
voltage, e.g. the «aponorm
Ensure that neither mains adapter nor cable are not
damaged.
1. Plug the adapter cable into the mains adapter socket 5 in the
blood pressure monitor.
2. Plug the adapter plug into the wall socket.
When the mains adapter is connected, no battery current is
consumed.
aponorm
®
Basis
®
by microlife
®
by microlife mains adapter avai-
®
by microlife 230V adapter».
11. Error Messages
8.
If an error occurs during the measurement, the measurement is
interrupted and an error message, e.g. «ERR 3», is displayed.
Error
Description Potential cause and remedy
«ERR 1» Signal too
The pulse signals on the cuff are too
weak
weak. Re-position the cuff and repeat
the measurement.*
«ERR 2» Error signal
During the measurement, error signals
were detected by the cuff, caused for
instance by movement or muscle
tension. Repeat the measurement,
keeping your arm still.
«ERR 3» No pressure
An adequate pressure cannot be gener-
in the cuff
ated in the cuff. A leak may have
occurred. Check that the cuff is correctly
connected and is not too loose. Replace
the batteries if necessary. Repeat the
measurement.
«ERR 5» Abnormal
The measuring signals are inaccurate
result
and no result can therefore be displayed.
Read through the checklist for
performing reliable measurements and
then repeat the measurement.*
«ERR 6» MAM Mode There were too many errors during the
«HI»
Pulse or cuff
The pressure in the cuff is too high (over
pressure too
300 mmHg) OR the pulse is too high (over
measurement in MAM mode, making it
high
200 beats per minute). Relax for 5
impossible to obtain a final result. Read
minutes and repeat the measurement.*
through the checklist for performing reli-
able measurements and then repeat the
«LO»
Pulse too
The pulse is too low (less than 40 beats
measurement.*
low
per minute). Repeat the measurement.*
«HI»
Pulse or cuff
The pressure in the cuff is too high (over
* Please consult your doctor, if this or any other problem occurs
pressure too
300 mmHg) OR the pulse is too high (over
repeatedly.
high
200 beats per minute). Relax for 5
If you think the results are unusual, please read through the
minutes and repeat the measurement.*
information in «Section 1.» carefully.
«LO»
Pulse too
The pulse is too low (less than 40 beats
low
per minute). Repeat the measurement.*
* Please consult your doctor, if this or any other problem occurs
repeatedly.
If you think the results are unusual, please read through the
information in «Section 1.» carefully.
15