After use
After use
After use or prior to prolonged stoppages in work, carry out the
following steps.
Disconnect the compressed air supply
Remove compressed air cartridge
Unscrew the compressed air cartridge from the thread of the
fitting.
The compressed air contained in the tool escapes audibly.
Pull the compressed air cartridge back out of the holder on the
tool.
Store the compressed air cartridge protected against blows and
dropping in the transport case supplied.
You can refill the compressed air cartridge using the PKT-
FILLMASTER 350 DF compressor available as an accessory.
You can also purchase a full compressed air cartridge in
exchange for an empty cartridge from your dealer.
Disconnect compressed air hose
Pull the quick coupler of the compressed air hose away from the
adapter.
The quick coupler is now released.
Disconnect the compressed air hose from the connection on the
adapter of the tool.
The compressed air contained in the tool escapes audibly.
Unscrew the adapter from the thread of the fitting.
Pull the adapter back out of the holder on the tool.
Store the adapter protected against blows and dropping in the
transport case supplied.
40