3.7 Device settings/visualisation
Note: All of the programable settings described in Part
3.7 can only be accessed and activated in the "PAUSE"
mode.
Visualisation of the menu screens/displays:
Note: The illustrations in the software schemes serve
for a better overview and are subsequently described.
In each menu screen the blue light bar highlights the
current active menu item or value set.
RINSE
ACTIVE
INACTIVE
SERVICE
INACTIVE
FLUSH TIME
INACTIVE
SETUP
EXIT
3.8 Main menu
The menu consists of 4 selectable menu items in which the
subsequent settings may be effected:
RINSE:
SERVICE:
FLUSH TIME:
permeate production
SETUP:
General device settings (date, time, language, limit values,
operating mode).
The recommended target values of all settings
are documented in the form "Form for set values
of BWT bestaqua 22,24,26 HQ" (see Part 7.1).
Document the parameters
the data at the device.
Please use the template at the end of the operating
instructions.
after you have set all of
3.8.1 Menu: SETUP
General settings:
Note: The change in the programming menu is avai-
lable from both the main screen "pause" as well as
from the detail overview display "PAUSE".
p a u s e
PERM 3.2 bar
PUMP
bar
_ _ _
25– 06 – 13 09 : 02
PAUSE
Confirm with the [ ] button to shift into the
programming menu.
AUTO RINSE
SERVICE
FLUSH TIME
SETUP
Fig. 10: Main selection menu: "SETUP"
The "SETUP" selection menu appears:
The menu item
is active.
"DATE"
Date ; time
DATE /
TIME
Conductivity value / TDS (ppm)
CONDUCTIVITY / TDS
Pressure tank operation: Yes/No
OPERATION MODE
Setting of the menu language
LANGUAGE
Quit menu and return to selection menu
BACK
Fig. 11: Display of the activated "SETUP" menu.
Perform the general settings of the "SETUP" selection menu in
accordance to: Fig. 12, Fig. 13, Fig. 14.
The description of the parameter setting "FLUSH TIME" is gi-
ven at Fig. 14.
_ _ _
16
EXIT
EN
37