Fein Slugger JME HoleMaker III Instrucciones De Uso página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

en
14
Filling the coolant container.
Prevent the flow of liquid along the cable into the socket outlet or into the core
WARNING
drill unit, as this can lead to electric shock. Tie a bow in the cable near the plug,
so that any liquid can drip off.
Do not use the magnetic core drill unit when the cooling-lubricant system is defective. Each
time before operating, check for tightness against leaks and for cracks in the hoses. Prevent liq-
uids from entering or penetrating electrical components.
Only use a coolant-lubricant emulsion (oil in water) as the cooling agent.
Observe the manufacturer's instructions on coolant.
Filling the mounted coolant container
(figure 3)
Unscrew the cap from the coolant container.
Fill in pump-feedable cooling lubricant, e.g.
Slugger cutting oil.
Screw the cap onto the coolant container
again.
Fig. 3
Upper closing cap
1.
3.
2.
Coolant container

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Slugger jme usa 202 m7 270 59 61 09 07 270 69 61 09 0

Tabla de contenido