Rotex RKHBH008BB3V3 Manual De Instalación página 92

Unidad interior para sistema de bomba de calor de aire-agua
Ocultar thumbs Ver también para RKHBH008BB3V3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 256
First
Second
code
code
Setting name
5
Equilibrium temperature and space heating priority temperature
00
Equilibrium temperature status (only in combination
with domestic hot water tank without electrical
booster heater (RKHTS), [4-03]=5, this setting is
fixed and can not be consulted)
00
Equilibrium temperature status (only in combination
with domestic hot water tank with built-in electrical
booster heater (RKHW*), [4-03]≠5)
01
Equilibrium temperature
02
Space heating priority status (only in combination
with domestic hot water tank without electrical
booster heater (RKHTS), [4-03]=5, this setting is
fixed and can not be consulted)
02
Space heating priority status (only in combination
with domestic hot water tank with built-in electrical
booster heater (RKHW*), [4-03]≠5)
03
Space heating priority temperature
04
Set point correction for domestic hot water
temperature (only in combination with domestic hot
water tank with built-in electrical booster heater
(RKHW*), [4-03]≠5)
6
DT for heat pump domestic water heating mode
00
Start
01
Stop
Scheduled storage and reheat domestic water heating
03
Scheduled time storage
04
Scheduled time storage start time
05
Scheduled time reheat or continuous reheat
06
Scheduled time reheat start time
07
Domestic hot water reheat set point
08
Domestic hot water reheat set point hysteresis
7
DT for booster heater and dual set point control
00
Domestic hot water step length (only in combination
with domestic hot water tank with built-in electrical
booster heater (RKHW*), [4-03]≠5)
01
Hysteresis value booster heater (only in
combination with domestic hot water tank with built-
in electrical booster heater (RKHW*), [4-03]≠5)
02
Dual set point control status
03
Second set point heating
04
Second set point cooling
8
Domestic water heating mode timer
00
Minimum running time
01
Maximum running time
02
Anti-recycling time (only in combination with
domestic hot water tank without electrical booster
heater (RKHTS), [4-03]=5)
02
Anti-recycling time (only in combination with
domestic hot water tank with built-in electrical
booster heater (RKHW*), [4-03]≠5)
03
Booster heater delay time (only in combination with
domestic hot water tank with built-in electrical
booster heater (RKHW*), [4-03]≠5)
04
Additional running time at [4-02]/[F-01]
Installation manual
39
Installer setting at variance with default value
Date
Value
Date
(a)
Default
Value
value
Range
1 (ON)
1 (ON)
0/1
0
–15~35
1 (ON)
0 (OFF)
0/1
0
–15~35
10
0~20
2
2~20
2
0~10
1 (ON)
0/1
1:00
0:00~23:00
0 (OFF)
0/1/2
15:00
0:00~23:00
45
30~50
10
2~20
0
0~4
2
2~40
0 (OFF)
0/1
10
1~24 / 25~55
7
5~22
5
0~20
30
5~95
0.5
0~10
3
0~10
50
20~95
95
0~95
Indoor unit for air to water heat pump system
Step
Unit
1
°C
1
°C
1
°C
1
°C
1
°C
1
1:00
hour
1
1:00
hour
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
min
5
min
0.5
hour
0.5
hour
5
min
5
min
RKHBH/X008BB
4PW62574-1 – 10.2010

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido