Field Settings Table - Rotex RKHBH008BB3V3 Manual De Instalación

Unidad interior para sistema de bomba de calor de aire-agua
Ocultar thumbs Ver también para RKHBH008BB3V3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 256

8.10. Field settings table

First
Second
code
code
Setting name
0
User permission level
00
User permission level
1
Weather dependent set point
00
Low ambient temperature (Lo_A)
01
High ambient temperature (Hi_A)
02
Set point at low ambient temperature (Lo_Ti)
03
Set point at high ambient temperature (Hi_Ti)
05
Weather dependent for cooling function
enable/disable
06
Low ambient temperature (Lo2_A)
07
High ambient temperature (Hi2_A)
08
Set point at low ambient temperature (Lo2_Ti)
09
Set point at high ambient temperature (Hi2_Ti)
2
Disinfection function
00
Operation interval
01
Status
02
Start time
03
Set point (only in combination with domestic hot
water tank without electrical booster heater
(RKHTS), [4-03]=5)
03
Set point (only in combination with domestic hot
water tank with built-in electrical booster heater
(RKHW*), [4-03]≠5)
04
Interval (only in combination with domestic hot
water tank without electrical booster heater
(RKHTS), [4-03]=5)
04
Interval (only in combination with domestic hot
water tank with built-in electrical booster heater
(RKHW*), [4-03]≠5)
3
Auto restart
00
Status
4
Backup/booster heater operation and space heating off temperature
00
Backup heater operation (only in combination with
domestic hot water tank without electrical booster
heater (RKHTS)
00
Backup heater operation (only in combination with
domestic hot water tank with built-in electrical
booster heater (RKHW*))
01
Backup/booster heater priority
02
Space heating off temperature
03
Booster heater operation (only in combination with
domestic hot water tank without electrical booster
heater (RKHTS))
03
Booster heater operation (only in combination with
domestic hot water tank with built-in electrical
booster heater (RKHW*))
04
Not applicable.
05
Not applicable.
06
Backup heater emergency operation
07
Backup heater second step
RKHBH/X008BB
Indoor unit for air to water heat pump system
4PW62574-1 – 10.2010
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
3
2/3
–10
–20~5
15
10~20
40
25~55
25
25~55
0 (OFF)
0/1
20
10~25
35
25~43
22
5~22
18
5~22
Fri
Mon~Sun, All
1 (ON)
0/1
23:00
0:00~23:00
60
fixed
70
55~80
60
40~60
10
5~60
0 (ON)
0/1
1 (ON)
0/1/2
1 (ON)
0/1
0 (OFF)
0/1/2
25
14~25
5
fixed
3
0/1/2/3/4
1 (enabled)
0/1
1 (enabled)
0/1
Step
Unit
1
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1:00
hour
5
°C
5
°C
5
min
5
min
1
°C
1
1
Installation manual
38

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido