GE IM-6D Manual Del Propietario E Instalación página 30

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALL WATER LINE CLAMP
3
Attach the water line clamp (strain relief) (17) from
the kit to the refrigerator. With the clamp directly
in line with the water valve, drive the screw (7)
from the kit through the clamp (17) at the indent
into the back of the cabinet.
The metal clamp is for the house water line (see
Water Line Installation Instructions). It is not to be
used for the tubing from the water valve up to the
icemaker.
CONNECT THE WATER LINE
4
• Make sure there is enough plastic water line to
water tube inlet
• Squeeze the ends of the hose clamp
kit with pliers and slide the clamp over the water
tube inlet.
• While still squeezing the clamp, insert the
plastic water line into the inlet as far as it will
• Then slide the clamp downward to capture the
plastic water line in place.
Water tube
inlet
Installation Instructions
7
17
ROUTE AND ATTACH THE PLASTIC
5
WATER LINE
Route the plastic water line along the back of
the refrigerator to the water tube inlet.
Fasten the plastic water line to the back of
the cabinet with three of the adhesive-backed
fasteners (5).
WATER VALVE INSTALLED
6
Refer to the Water Line Installation Instructions for
connection to the home water supply. After water
line installation is completed, set the icemaker
power switch to ON.
The icemaking cycle will not begin until the
icemaker and freezer compartment reach
operating temperature, then icemaking will
begin automatically.
REINSTALL THE COVER
7
Reinstall the compressor compartment access
cover. This requires using the screws you removed
previously to reattach the cover to the back of the
refrigerator case. This must be reinstalled for your
refrigerator to function properly.
29
Adhesive-backed
fasteners for
plastic water line

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido