CONNECT THE WATER LINE
4
• It may be necessary to remove the screw from
the top right condenser mounting clip for better
access to the water tube inlet.
• Make sure there is enough plastic water line to
water tube inlet
• Squeeze the ends of the hose clamp
kit with pliers and slide the clamp over the water
tube inlet.
• While still squeezing the clamp, insert the
plastic water line into the inlet as far as it will go
• Then slide the clamp downward to capture the
plastic water line in place.
• Make sure the fill tube is aimed down.
• If the condenser mounting screw was removed,
secure the condenser to the refrigerator by
replacing the mounting clip and screw.
• Do not overtighten the screw.
Water tube
inlet
ROUTE AND ATTACH THE PLASTIC
5
WATER LINE
Fasten the plastic water line to the back of the
cabinet with adhesive-backed fasteners (5), spacing
the fasteners as shown to take up slack
in the line. (It may be necessary to remove the screw
from the top right condenser mounting
clip for better access to the water tube inlet.)
Adhesive-backed fasteners
for plastic water line
Installation Instructions
25
WATER VALVE INSTALLED
6
Refer to the Water Line Installation Instructions for
connection to the home water supply. After water
line installation is completed, set the icemaker
power switch to ON.
The icemaking cycle will not begin until the
icemaker and freezer compartment reach
operating temperature, then icemaking will
begin automatically.
REINSTALL THE COVER
7
Reinstall the compressor compartment access
cover. This requires using the screws you removed
previously to reattach the cover to the back of the
refrigerator case. This must be reinstalled for your
refrigerator to function properly.