4.8
Adjusting the flow rate of the motor pump
The flow rate of the motor pump depends on a number of parameters: the motor speed, the suction and discharge head and the
quality of the liquid to be pumped all affect the flow rate of the motor pump.
To increase the flow rate of the motor pump:
1.
Place the throttle lever (A11) in the "MAX" position.
2.
Increase the head height.
ST2.36H - TR2.36H
4.9
Stopping the motor pump
1.
Return the throttle lever (A11) to its original position.
2.
Move the switch (A1) to "OFF".
The motor pump stops.
3.
Close the fuel tap (A9)
4.
Disconnect the suction and discharge pipes and allow the liquid to flow out.
5.
Leave the motor pump to cool, ensuring that it is well ventilated (risk of fire or burns).
6.
Drain the motor pump then rinse it out when you have finished using it for the day.
A = Head height (m) - B = Flow rate (L/min)
HP2.26H
To reduce the flow rate of the motor pump:
1.
Place the throttle lever (A11) in the "MIN" position.
2.
Decrease the head height.