4.10 Rinsing the motor pump
After the motor pump has stopped and cooled down:
1.
Set the switch (A1) to OFF.
2.
Drain the suction and discharge hoses, leaving the liquid to flow out.
3.
Remove the drain plug from the pump (A13) to empty the pump body (A8-E6) then refit the it once drainage is complete.
4.
Remove the filler cap from the pump (A7) and fill the pump body with fresh water.
5.
Slowly pull the starter-recoil reel handle (A12) several times until there is some resistance then let it return gently.
6.
Unscrew the drain plug on the pump and leave the water to flow out.
7.
Screw the filler cap and drain plug back on.
8.
Repeat the operation if necessary.
9.
Clean the suction strainer (E5): remove any dirt and rinse with fresh water.
5 Servicing the motor pump
As a safety measure, maintenance should be performed on the generating set regularly and carefully by people who have the
necessary experience and are equipped with suitable tools, in respect of current regulations. The maintenance operations to be
carried out are detailed in the maintenance table. The interval for this is supplied as a guide and for generating sets operating with
fuel and oil which conform to the specifications given in this manual. The maintenance intervals can be shortened depending on the
generating set's operating conditions and requirements. It is important to note that the warranty shall not be valid if generating set
maintenance has not be performed correctly.
5.1

Reminder of use

Ensuring maintenance is performed regularly and correctly will guarantee safety and performance. The oil, filter elements and,
where present, the spark plug, are consumables which must be in good condition for the unit to operate correctly.
Replace them regularly as often as is needed (the reference for ready-to-use maintenance kits is given in the table of
technical specifications where applicable). The warranty becomes void in the event of failure to respect the maintenance
recommendations. For any questions about a special operation, please contact your nearest agent who will advise and help you.
5.2
Maintenance intervals table
Operation to be carried out at whichever deadline
is reached first:
Clean the unit
Unit
Replacing the spark plug
Oil
Clean the screen filter
Fuel
Clean the sediment bowl
Clean the foam element
Replace the paper element
Air filter
Replace the foam element
Part numbers of parts to be used during maintenance:
5.3
Performing the maintenance operations
1.
Shut down the unit and wait at least 30 minutes for it to cool.
2.
Disconnect the cap(s) of the spark plug(s) and disconnect the "-" terminal on the battery (if fitted).
3.
Carry out maintenance in accordance with the information given in this manual and, to avoid the risk of damage to the unit,
only use original parts or their equivalent.
5.3.1 Top up the oil
The oil must be recycled or disposed of in accordance with applicable local regulations. In order for the drain operation to be more
effective, it is advisable to run the unit for a few minutes before draining to make the oil more fluid.
1.
Place an appropriate container under the oil drain screw (A14-B5).
2.
Remove the oil drain screw and the oil dipstick/filler plug (A2-B1).
3.
After draining completely, screw the oil drain screw back in.
4.
Top up with oil that complies with the technical specifications in this manual, then check the level.
5.
Refit and tighten the oil dipstick/filler plug.
6.
After filling, check that there are no oil leaks, and wipe away any traces of oil with a clean cloth.
5.3.2 Clean the screen filter
1.
If fitted: close the fuel tap.
2.
Unscrew the fuel tank cap (A3).
3.
Remove the screen filter (A4) located inside the fuel tank.
4.
With a low-pressure dry air gun, blow air through the screen filter, from the outside inwards.
5.
Rinse it using clean fuel and dry it. Replace it if it is damaged.
6.
Put the screen filter back inside the tank and screw the cap back onto the fuel tank.
After:
1
Change
Every:
st
month/first
3 months/50
20 hours
hours
X
X
X
X
18/155
Every:
Every:
6 months/100
2 years/300
hours
hours
X
X
General
X
maintenance
must only be
X
carried out by
X
one of our
agents.
X
France:
0.806.800.107
X
(call charge)
Ready to use
maintenance kit

Publicidad

Tabla de contenido
loading

Tabla de contenido