Repairing Minor Faults; Technical Specifications; Operating Conditions - Kohler AQUALINE ST 2.36 C5 Manual De Utilización Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29

7 Repairing minor faults

7.1
Diagnostics for minor faults
The motor pump...
Does not start
Stops
Does not function normally
(self-priming, noise, smoke,
etc.)
Is not discharging, or the flow
rate is insufficient
*France: 0.806.800.107 (call charge)
7.2
Replace the spark plug.
1.
Disconnect the spark plug cap (F1).
2.
Use a dry air spray to clean the spark plug wells.
3.
Use a spark plug spanner to unscrew the spark plug (A16-F2) and discard it.
4.
Fit a new spark plug in position and tighten it by hand to avoid damaging the threads.
5.
Use a spark plug spanner to tighten the spark plug by 1/2 turn after it is seated to compress the washer.

8 Technical specifications

8.1

Operating conditions

The stated outputs of the units are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
The unit's output is reduced by approximately 4% for every additional 10°C and/or approximately 1% for every additional 100m in
altitude. Units can only operate while stationary.
Check that:
The checks before starting have been
performed.
YES
The fuel tap is open.
YES
The throttle lever is positioned to 1/3 of
the "MIN" position.
YES
The switch is set to "ON".
YES
The spark plug is in good condition and
correctly connected.
YES
The oil level is correct.
YES
The fuel level is correct.
YES
The air filter is in good condition.
YES
Self-priming is taking place.
YES
Maintenance has been correctly
performed on the motor pump
components.
YES
Have the motor pump checked by one
of our agents.*
The throttle lever is positioned to
"MAX".
YES
The suction head height is correct.
YES
The suction circuit is correct.
YES
Have the motor pump checked by one
of our agents.*
20/155
Solutions to be applied:
Perform the necessary checks.
NO
Open the fuel tap.
NO
Position the throttle lever to 1/3 of the
"MIN" position.
NO
Set the switch to "ON".
NO
Check the spark plug.
NO
Top up with oil.
NO
Fill up with fuel.
NO
Clean the air filter.
NO
Check the level of liquid (to be aspirated
and in the pump body) and check the
NO
suction circuit for leaks.
Perform maintenance on the motor pump
NO
as per the recommendations.
Position the motor throttle lever to the
"MAX" position.
NO
Lower the height of operation.
NO
Check the suction duct (absence of leaks,
kinks in the hose, etc.).
NO

Publicidad

Tabla de contenido
loading

Tabla de contenido