Getting started - up to 100 Fronius IG TL inverters via
an RS 422 interface
General
The following steps must be carried out in order to be able to use the interface protocol:
1.
2.
3.
4.
5.
Important The baud rate does not have to be set for this inverter.
Setting the
inverter number
Assign a separate inverter number to each inverter
Activate the interface protocol for each inverter
Connect inverters using a patch cable
Connect the photovoltaic system to a 3rd party device (PC, converter, etc.) using
the patch cable
Insert the terminating plug into the last free 'IN' socket
1.
Select 'Inverter Number' in the Setup
menu
2.
Press the 'Enter' key
The inverter number is shown, the
first digit flashes.
3.
Use the 'Up' and 'Down' keys to
select a value for the first digit
4.
Press the 'Enter' key
The second digit flashes.
5.
Use the 'Up' and 'Down' keys to select
a value for the second digit
6.
Press the 'Enter' key
6