6.3. Servicing
• Do not attempt to repair the equipment yourself.
• This equipment does not contain any components that can be repaired by the user.
• Removing panels or covers could expose you to hazardous electric shocks.
• In no event is cutting off the mains power supply sufficient to protect you against electrical shocks (due to the presence of capacitors).
• Cut off the power supply if the equipment emits abnormal noises, odours or smoke and contact your installer immediately.
• Cut the power supply to the equipment before performing any cleaning.
• Do not use aggressive cleaning fluids or solvents to clean the equipment.
• Do not user pressure sprays to clean the air terminals. You risk damaging the air heat exchanger and introducing water into the electrical circuits.
6.4. Operating anomalies
Anomaly
Filter indicator lamp lit
Fault indicator lamp lit
Insufficient airflows at terminals
Noisy product
The product does not start
6.5. Spare parts list
Refer to the Aldes document: InspirAIR
7. WARRANTY
7.1. General warranty terms and conditions
Refer to the general terms and conditions on the www.aldes.fr site. The system must be installed by a qualified professional in compliance with best practices,
the standards in force and the recommendations in our instructions. The system must be used normally and regularly serviced by a specialist.
7.2. Warranty period
The product is covered by a two-year parts warranty (excluding labour). The warranty period is effective from the purchase date of the product, as proven by
the invoice.
7.3. Warranty exclusions
The following are excluded from this warranty: installation failure due to failure to comply with manufacturer recommendations, including lack of airflow water
trap, and with standards and regulations in effect, or lack of servicing.
7.4. After-sales service:
In the event of a problem, please contact your installer or retailer.
This product must not be disposed of with household waste. At the end of its life or if replaced, it returned to a retailer or sent to a collection
centre. ALDES belongs to the Ecosystem eco-body www.ecosystem.eco
- Filters need replacing
- Motor problem
- Temperature probe problem
- Ductwork incorrectly balanced
- Leaks in the ductwork
- Aeraulic ductwork crushed or has too many
elbows
- Product configuration not suited to the dwelling
- Filters clogged
- Waiting time too short
Top after-sales service guide.
®
Cause
- Replace the filters see 6.1
- Cut power for 30 seconds and reset
- Contact your installer if the product does not
restart
- Verify the ductwork branch lengths
- Seal the ductwork better
- Verify the ductwork
- Verify the product configuration see 5.3
- Replace the filters see 6.1
- Wait 30 s to 1 mn before switching on
26
Remedy