Operating Controls - Nilfisk Advance Proterra Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

55
54
53
52

OPERATING CONTROLS

ENGLISH
10
51. Charged battery warning light:
When all yellow LEDs are on, the batteries are charged.
Residual autonomy depends on battery capacity and
working conditions.
When the red LED is on, batteries are discharged. The
autonomy is over, the batteries must be recharged (see
the procedure in the relevant paragraph).
52. Side broom lever:
("forward" position) side broom lowered
("backward" position) side broom lifted
53. Main broom lever:
("forward" position) main broom lowered
("backward" position) main broom lifted
54. Hopper lever:
("forward" position) hopper lowered
("backward" position) hopper lifted
55. Hopper dumping door lever
("forward" position) dumping door opened
("backward" position) dumping door closed
51
56
57
63
INSTRUCTIONS FOR USE
Proterra™ - 33019867
58
59
60
64
56. Hour counter
57. Ignition key:
and disables all machine functions.
When turned to "I", it enables the machines functions
When turned to "II" it starts the main motor.
As soon as the main motor starts, release the key,
which returns to "I".
58. Horn switch
59. Vacuum fan/Shaker switch:
(upper position) vacuum fan and dust guard system
activation
60. DustGuard™ system switch (optional)
61. Working light switch (optional)
62. Steering wheel adjustment lever (optional)
63. Hopper overtemperature warning light (optional)
64. Clogged hopper filter warning light
When turned to "O", it turns the electrical system off
(lower position) filter shaker activation
61
62
revised 08/2018
09/2010
P100336

Publicidad

Tabla de contenido
loading

Tabla de contenido