FUSE CHECK/REPLACEMENT/RESET

revised 08/2018
Circuit breaker check
Fuse check/replacement
09/2010
1.
2.
Engage the parking brake.
3.
Turn the ignition key (57) to "O" and remove it.
4.
On the panel (38), check for deactivation of one of the following fuses (Fig. 8):
(A): F1 (10 A), dust vacuuming
(C): F4 (16 A), ignition key
(D): F5 (10 A), motor auxiliary
(E): F3 (2 A), DustGuard system (if equipped)
(F): F6 (10 A), working lights (optional)
(G): F8, cab blower (optional)
Reset any deactivated fuse, when the component that caused deactivation has fully cooled down.
1.
2.
Engage the parking brake.
3.
Turn the ignition key (57) to "O" and remove it.
4.
Open the fuse box cover (23).
5.
Check the following fuses (Fig. 9) for integrity:
(A): F0 (250 A), main pump motor
(B): F10 (30 A) (B), auxiliary circuits
Replace any open fuse. Install the cover.
6.
Close the fuse box (23).
Drive the machine on a level floor.
(B): F2 (10 A), filter shaker
Drive the machine on a level floor.