Dustguard™ System Water Filter Cleaning (Optional); Hydraulic System Oil Level Check - Nilfisk Advance SW5500 Instrucciones De Uso

Ocultar thumbs Ver también para Advance SW5500:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DUSTGUARD™ SYSTEM WATER FILTER CLEANING (OPTIONAL)

HYDRAULIC SYSTEM OIL LEVEL CHECK

09/2016
NOTE
system tank (23).
1.
Drive the machine on a level ground.
2.
Turn the ignition key (51) to "0" and engage the parking
brake.
3.
Lift and remove the left side panel (32) to reach the water
4.
Unscrew and remove the transparent cover (B) with the
5.
Clean and install them on the support (E).
NOTE
holder.
WARNING!
Procedure to be performed with the hopper (11)
fully retracted.
1.
Turn the ignition key (51) to "0" and engage the parking
brake.
2.
Open the engine compartment hood (19) and fasten it with
the support rod (44).
3.
Check that the oil level in the hydraulic system tank (43) is
between the minimum (MIN) and maximum (MAX) marks
4.
If necessary, add oil through the plug (A), using the oil
5.
Remove the support rod (44) and close the hood (19).
To prevent water from flowing out when cleaning the
filter, turn on the dust guard system and empty the
filter assembly (A, Fig. 22) of the dust control system.
gasket (C), then remove the filter strainer (D).
Install the gasket (C) and the filter strainer (D) in
the housings of the cover and of the filter assembly
shown in figure 23.
specified in Technical Data paragraph.
INSTRUCTIONS FOR USE
1467287000 - SW5500
Figure 22
Figure 23
E
C
A
MAX
MIN
ENGLISH
P100916
P100917
A
B
D
31

Publicidad

Tabla de contenido
loading

Tabla de contenido