Diamond AP1CH/F86-R2 Manual De Instalación, Uso Y Mantenimiento página 34

Armario chocolate
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Switch on/off of the Controller
EVCO
FW 111105
1.02
pressing the ON/OFF key
the firmware version.
Program 17
Set
Ice cream
seconds the display shows the program number
loaded and the description (if the program
inserted is among the 19 present in the controller).
This message persists for a few seconds.
If Set appears after the program number, it means
the setpoint or relative humidity has been
changed.
Room
+20.0°C
PullDown
indicates the start of the first temperature descent,
defined as PULL-DOWN.
OFF
pressing the
key for 5 seconds, the controller
displays the OFF screen: in these conditions all
controller outputs are forced off and the controller
itself enters a low consumption function mode
(equal to about 0.3W).
Display During Normal Functioning
The temperature of the cell swings between the
setpoint value set (value reached where the
compressor is switched off) and the value of the
differential (value reached where the compressor
is switched on).
The first line of the display shows the temperature
of the cell, while the second line shows the
functioning status of the compressor.
Message with compressor on:
Room
-17.5°C
Comp.ON
Message with compressor off:
Room
-17.5°C
Comp.OFF
Pressing the
key allows to select the display
as follows:
Room
-17.5°C
Comp.ON
On activation of defrosting, the display is as
follows.
On
switch-on
by
the display shows
After
a
few
more
The successive display
On
switch-off
by
12/02/04
18:54:31
Message during defrosting:
Room
-17.5°C
Defrost
 Message during the dripping phase:
Room
-17.5°C
Dripping
 Message during recovery after defrosting:
Room
-17.5°C
Recovery
Notes: on activation of a defrosting cycle, the cell
temperature may undergo a positive variation,
therefore increasing the value.
Light Switch on/off
In the models with glass door the lights in the cell
can be kept on constantly. This function can be
activated by following the procedure below:
press the
key, the controller displays the
Light
following screen:
press the
key, the controller displays the
Light
following screen:
press the
menu key to go back to the normal
display
In all other models the cell light is automatically
activated on opening the door.
Selection Menu
By pressing the
functioning, menu selection can be entered. Press
the
and
available menus.
If no keys are pressed within 10 seconds, the
controller
automatically
display.
Menu list:
Setpoint variation menu
Menu 01
Setpoint
Humidity variation menu
Menu 02
Humidity
Defrosting start menu
Menu 3
Defrost
7
ENGLISH
OFF
ON ?
ON
OFF ?
MENU key during normal
keys to scroll through the
reproposes
normal
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ae68x2540-dm

Tabla de contenido