Diamond AP1CH/F86-R2 Manual De Instalación, Uso Y Mantenimiento página 43

Armario chocolate
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
A19
Cond Probe
S 17:58 01/12/03
A19
Cond Probe
E 02:22 02/12/03
 DEFROST ended due to Time Out:
A1
TimeOut Def
S 02:39 27/11/03
A16
TimeOut Def
Time:
GB
 Compressor Use:
A16
Use Compres
S 02:39 27/11/03
A12
Use Compres
E 04:21 04/11/03
 High Condensation Temperature:
A19
High T Cond
S 17:58 01/12/03
A19
High T Cond
E 02:22 02/12/03
 Dirty Condenser:
A12
Dirty Cond
S 17:58 01/12/03
A12
Dirty Cond
E 02:22 02/12/03
 Low Evaporation Temperature:
A12
Low T Evap
S 17:58 01/12/03
A12
Low T Evap
E 02:22 02/12/03
Inverted Probes
Err
Probe Invert
↓Mute
technician in charge can activate a "CYCLE
TEST"; if during the first phase of this cycle the
controller detects the incorrect reading of the
cell/evaporator probe, it generates an alarm
message and activates the buzzer. The event is
recorded in the faults memory.
The buzzer is silenced by pressing the
The message remains displayed until switch-off or
on controller memories reset.
30 min
AST↓
During installation, the
Cell Probe Fault
Err
Room Probe
↓Mute
fault generates the alarm message and activates
the buzzer... The event is recorded in the faults
memory.
The buzzer is silenced by pressing the
Notes: during the cell probe error event, the
adjustment is timed. The compressor functioning
times are the average functioning times calculated
by the controller in the day before the fault.
If average compressor times are not available,
functioning
parameters pre-set by the manufacturer.
Evaporator Probe Fault
Err
Evap Probe
↓Mute
fault generates the alarm message and activates
the buzzer. The event is recorded in the faults
memory.
The buzzer is silenced by pressing the
during
Notes:
activation of the defrosters takes place for
intervals of time and with maximum duration
according to the parameters pre-set by the
manufacturer.
Condenser Probe Fault
Err
Cond Probe
↓Mute
fault generates the alarm message and activates
the buzzer. The event is recorded in the faults
memory.
The buzzer is silenced by pressing the
Notes: during the probe error intervention the
"high
condensation
condenser" alarms are no longer managed.
Maximum Defrosting Time
Err TimeOut Def
↓Mute
with the following coincident conditions:
 End of defrosting, maximum time has
been reached
 Evaporator probe temperature lower than
0°C
The probable cause is the malfunctioning of the
key.
defrosting circuit.
16
AST
An adjustment probe
takes
place
by
means
AST
An evaporator probe
the
evaporator
probe
AST
An evaporator probe
temperature"
AST
This alarm only occurs
key.
of
the
key.
error,
key.
and
"dirty