Installation; Packaging And Unpacking - Diamond AP1CH/F86-R2 Manual De Instalación, Uso Y Mantenimiento

Armario chocolate
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Compressor Times
Err Use Compress
↓Mute
AST
functioning of the compressor that exceeds 90 %
of daily use generates the alarm message and
activates the buzzer. The event is recorded in the
faults memory.
The buzzer is silenced by pressing the
Notes: during compressor functioning the cell
probe will not be managed but will be timed on the
basis
of
the
parameters
manufacturer.
High Condensation Temperature
Err
High T Cond
↓Mute
AST
value set, relative to the temperature detected by
the condenser probe, generates the alarm
message and activates the buzzer. The event is
recorded in the faults memory.
The buzzer is silenced by pressing the
In this state all of the outputs are deactivated
except for the condenser fan output. On return of
the temperature below the safety threshold, the
controller resets normal functioning.
8.

INSTALLATION

8.1.

Packaging And Unpacking

Move and install the appliance respecting the
information provided by the manufacturer, shown
directly on the packaging, on the appliance and in
this manual.
The lifting and transportation system of the
packaged product envisages the use of a fork-lift
truck or a pallet stacker, using which particular
attention must be paid to balancing the weight in
order to prevent the risk of overturning (avoid
excessive tilting!).
!
ATTENTION: When inserting the lifting
device, pay attention to the gas supply pipe and
the position of the feet.
!
ATTENTION: given the presence of weights
concentrated in the high part of the appliance, do
not drag the appliance during movements (tipping
hazard and damage to feet).
The packaging is made of cardboard and the
pallet of wood. A series of symbols is printed on
The
continuous
key.
pre-set
by
the
Exceeding the safety
key.
17
Dirty Condenser Warning
Err
Dirty Cond
↓Mute
AST↓
the minimum and maximum value of the
temperature detected by the condenser probe
constantly updated. The values are updated at
every compressor cycle. If the difference between
minimum and maximum is greater than the value
set the alarm message is generated and the
buzzer is activated. The event is recorded in the
faults memory. The buzzer is silenced by pressing
the
key.
Low Evaporation Temperature
Err
Low T Evap
↓Mute
AST↓
safety value set, relative to the temperature
detected by the evaporator probe, generates the
alarm message and activates the buzzer. The
event is recorded in the faults memory.
The buzzer is silenced by pressing the
In this state a protection defrosting is activated.
the cardboard packaging which highlights, in
accordance with international standards, the
provisions which the appliances must be subject
to during loading, unloading, transportation and
storage.
TOP
FRAGILE
HANDLE
WITH CARE
On delivery, check that the packaging is intact and
has
not
suffered
any
transportation.
Any damage must be notified to the transportation
company immediately.
The appliance must be unpacked as soon as
possible to check that it is intact and undamaged.
ENGLISH
The controller keeps
Lowering beyond the
key.
DO NOT EXPOSE
TO HUMIDITY
damage