Diamond AP1CH/F86-R2 Manual De Instalación, Uso Y Mantenimiento página 36

Armario chocolate
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Menu 05: List of HACCP Alarms
If in Menu 05 the
key is pressed, enter the
HACCP alarms display mode.
If there are no alarms recorded "No Data" is
No Data
displayed:
If alarms are recorded, the time of the start of the
last alarm with the progressive alarm number from
A01 to A32 are displayed. By pressing the
key, further information is given relative to the
alarm. If the alarm is still in progress the display
shows Present.
By pressing the
and
alarms in the memory can be displayed.
Exit by pressing the
key.
Below is an example of data recorded in the case
of a "high temperature" alarm:
A28
High T Room
S17:14
06/02/04
A28
High T Room
Time
2h47min
A28
High T Room
Temp Max
A28
High T Room
Present
Menu 06: List of Alarms E Faults
The display of a functional fault is priority on the
HACCP alarms.
If in Menu 06 the
key is pressed, enter the
alarms and faults display mode.
If there are no alarms or faults recorded "No Data"
No Data
is displayed:
Up to 32 alarms/faults can be recorded with the
relative information. By pressing the
keys, any other alarms in the memory can be
displayed.
Below is an example of data recorded in the case
of a "cell probe" fault:
keys, any other
+10°C
and
Number of faults recorded
A05
Room Probe
S 10:42 11/12/03
Date/time of occurrence
Menu 01: Print
In the models with printer, if the
pressed in menu 07, enter the print mode. The
possible prints are:
HACCP - last 32 HACCP alarms recorded
Print 01
HACCP
Faults - last 32 faults memorised
Print 02
Failures
DAILY - all memorised recordings
Print 03
Daily
The successive pressing of the
allows to scroll the display of the types of printing.
To select press the
printing has been selected
press the
key for 5 seconds to start it. Press
to go back to the previous menu.
Printing examples:
DAILY Print
1:50 End of Defrosting
Cell
1:30
Defrosting
1:00 Cell
00:00:00 Cell
Date: 15/09/2004
N 1 Ice-cream
Setpoint
––––––––––––––––––––––
DAILY
9
ENGLISH
Type of fault
of the fault
key is
and
keys
key. Once the type of
-17.5°C
Start
of
-17.5°C
-18.5°C
-20°C
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ae68x2540-dm

Tabla de contenido