The column tilts violently or too
slowly
Incorrect outlet regulator setting.
➥ Adjust the outlet regulators.
Hare: speed increase.
Tortoise: speed reduction.
Tyre pressure gauge needle fails
to return to 0
Pressure gauge faulty or damaged.
➥ Replace the pressure gauge.
WARNING
The "Spare parts" handbook does not
authorise the user to carry out work
on the machine with the exception of
those operations explicitly described
in the User Manual. It only enables the
user to provide the technical assistan-
ce service with precise information, to
minimise delays.
MAINTENANCE
WARNING
SIMPESFAIP declines all responsibility
in the event of claims resulting from
the use of non-original spare parts or
accessories.
WARNING
Do not attempt to modify the pressure
settings for relief valves or the pres-
sure limiter for any reason whatsoever.
The manufacturer declines all liability
for damage resulting from tampering
with these valves.
WARNING
Before adjusting or servicing the ma-
Operator's manual M 824 LL
chine, disconnect the electricity and
compressed air supplies and ensure
that all moving parts are suitably
immobilised.
WARNING
Do not remove or alter any part of this
machine (only technical assistance
personnel is permitted to do so).
DANGER
When the machine is disconnected
from the air supply, the devices bear-
ing the sign shown above may remain
pressurised.
The purpose of the regulator filter unit plus
lubricator (FRL) is to filter the air, adjust
the pressure and lubricate it.
The "FRL" unit supports a maximum input
pressure of 18 bar and has an adjustment
range of 0.5 to 10 bar. The setting may
be modified by pulling the handle out and
then turning. After adjusting, return the
handle to the locked position by pushing
down (fig.35a).
The lubricant flow-rate is adjusted by
turning the screw on part "L", (fig.35b);
normally this unit is precalibrated to a
pressure of 10Bar, with SAE20 viscos-
ity lubricant in order to make a drop of
lubricant come out, which can be seen
from the specific cover, every 4 times the
bead breaker is operated.
DANGER
Before carrying out any maintenance
operation or topping up with lubricant,
disconnect the machine from the com-
pressed air supply line.
Periodically check the lubricant level
through the specific windows and top up
as shown in fig.35c. Top up only with non-
detergent SAE20 oil equal to 50cc.
The filter regulator "FR" has an automatic
EN