Troubleshooting
If you run into unexpected trouble, look first for a solution in the tables below. If you
are still having trouble after trying the suggested solution, call 833-353-5483(USA),
844-509-4659(CANADA).
Gas safety
Problem
You smell gas.
Surface burner
Problem
All burners do not
light.
Surface burners do
not light.
DOP30T840GS_DG68-01458A-00_EN+MES+CFR.indb 95
DOP30T840GS_DG68-01458A-00_EN+MES+CFR.indb 95
Possible cause
The surface burner knob is
not in the Off position and
the burner is not lit.
There is a gas leak.
Possible causes
The power cord is not
plugged into the electrical
outlet.
A fuse in your home may
be blown or the circuit
breaker may have tripped.
The gas supply is not
properly connected or
turned on.
The control knob is not set
properly.
The burner caps are not in
place.
The burner base is
misaligned.
Action
Turn the burner knob to Off.
Clear the room, building, or area of all
occupants.
Immediately call your gas supplier
from a neighbor's phone. Do not call
from your phone. It is electrical and
could cause a spark that could ignite
the gas. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier,
call the fire department.
Action
Make sure the electrical plug
is plugged into a live, properly
grounded outlet.
Replace the fuse or reset the circuit
breaker.
See the Installation Instructions that
came with your range.
Push in the control knob and turn it to
the Lite position.
Clean the electrodes.
Put the burner cap on the burner
head.
Align the burner base.
English 95
2023-01-12 오후 2:41:25
2023-01-12 오후 2:41:25