2. Setting the DIP switch

1 DIP SW1
Function
Change of needle bar stop height (It is possible to set ±7 stages by combination of the set value of DIP SW1-1 to -3 and the code setting of DIP SW2-1.)
SW1-1
SW1-2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
2 DIP SW2
Function
SW2-1
Selection of needle bar UP stop position code
SW2-2
Thread trimming speed setting
SW2-3
Unused
SW2-4
Unused
SW2-5
Unused
SW2-6
Unused
SW2-7
Unused
SW2-8
Unused
3 SLIDE SW3
Function
Unused
54
3
1
2
SW1-3
SW1-4(unused)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
High
250sti/min
-
-
-
-
-
-
State of delivery
3 side ON
By changing DIP SW1 1, DIP SW2 2, and SLIDE
SW3 3 mounted on the control box, the setting can
be changed as described in the following table.
• Perform the change of the DIP SW
and SLIDE SW after turning OFF the
power switch.
• Do not turn ON the switch not used
yet.
Set value
Needle tip height at the time of UP stop
0
The height depends on the set value of DIP switch SW2-1 2.
(State of delivery)
1
2
ON/Needle stop position - high
3
OFF/Needle stop position - low
4
5
6
7
OFF
Low
400sti/min
-
-
-
-
-
-
DIP SW2-1
State of delivery
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF