Descargar Imprimir esta página

Angelo Po FX 82 G3T Manual De Uso E Instalación página 125

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

CONVERSION OF GAS SUPPLY
The constructor has tested the appliance with its own
mains gas, identified by the sticker applied to the
nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 – Turn off the gas supply tap (A).
2 – Change the burner nozzle (see page 62).
3 – Remove the testing gas sticker from the dataplate
(B) and apply the new one to identify the gas being
used.
4 – Remove the sticker from the appliance and apply
the new one (C) with the category of the country of in-
stallation.
5 – Access the "Service" menu and activate the "Gas
type conversion" procedure (see page 9).
6 – Carry out the appliance testing procedure (see
page 59).
Important
On completion of the operation, make sure that
there are no gas leaks or malfunctions.
TESTING OF THE APPLIANCE
Important
Before it is put into service, the system must be tested to check the operating
conditions of every single c omponent and ide ntify any malfunctions. In t his
stage, it is important to check that all health and safety requirements have been
complie.d with in full.
To test the system, make the following checks.
1 – Turn on the gas and water supply taps and check that the connections are tight.
2 – Turn on the master switch to check the electrical connection.
3 – Check that the mains gas is the same as that used for commissioning of the appli-
ance, and carry out the conversion procedure if necessary (see page 59).
4 – Check that the gas pressure conforms to the values stated in the table at the back
of the manual.
5 – Check that the combustion exhaust gases comply with the requirements (see page
54).
6 – Check the water pressure and adjust if necessary (see page 61).
7 – Check that the safety device is operating correctly.
8 – Carry out a cooking cycle without food to ensure that the appliance is operating
correctly.
After testing, if necessary instruct the user in all the skills necessary for putting the ap-
pliance into operation in conditions of safety, in accordance with legal requirements.
Important
During performance of the test procedure and on completion of the operation,
make sure that there are no gas leaks or malfunctions.
English
C
IT-AL-BG-CH-CZ-ES-GB-GR-HR-IE-MK-PT-RO: II2H3P - PL: II2E3P
G20 20mbar
(2H) (2E)
NL-RO: II2L3B/P
AT-CH: II2H3B/P DE:II2E3B/P
B
G20
m3/h
G31
kW
mbar
G25
m3/h
mbar
kW
G30
kW
Kg/h
mbar
G20
G31
kW
m3/h
mbar
kW
G25
m3/h
kW
mbar
G30
kW
mbar
Kg/h
- 59 -
BE: II2E(S)B3P - FR: II2Esi3P
FR: II2Esi3+
G30/G31 28-30/37mbar (3+)
G31 37mbar (3P)
LU: I2H
LU: I3+
NL: II2L3P
G30/G31 28-30/37mbar (3+)
AT: II2H3P
IS-MT: I3B/P
HU: II2HS3B/P
A
01
rif.
0051
kW
Kg/h
mbar
~
~
CE n.
~
TYPE
01
rif.
0051
mbar
Kg/h
~
~
CE n.
~
TYPE
IDM-39619300800.tif
Use and installation manual
IT
GB
DE
FR
ES

Publicidad

loading

Este manual también es adecuado para:

Fx 82 g3ctFx 122 g3t