7
Emergency electric lock installation (ACG9487B)
The "emergency" lock device is considered a safety lock because in case of a
power failure, or in the event of a fault, the doors can be manually moved.
7.1 - Fasten the two brackets to the carriages using the 4 screws A
A
7.2 - In the specific strokes, insert the 4 hex head screws B as in the figu-
re. Then, fasten the electric locking unit using the 4 nuts C.
Pay attention to correct alignment of the electric lock pin with the holes in
the brackets.
B
C
7.3 - Pass the lever unlocking cord as indicated in the figure, then fasten it
on the end with the specific stop
Fasten the manual unlocking lever in the desired position using the hole F.
Adjust the tightening of the steel cable C with the lever L in the
"unlocking" position and bracket S turned completely SX.
For further adjustments, use the adjustment screws R.
L
IMPORTANT: Set the TYLK parameter of the ADV menu on LK2
Apply a table that indicates the near to the release lever
manual door release mode.
7.4 - Connect the electric lock output to the LK terminals of the command
control unit.
R
S
8
F
-
+
LK
F
R
V