13.3 INTERLOCKING OF TWO AUTOMATIONS
RED
YELLOW
BROWN + GREY + WHITE
GREEN+BLUE
PINK
GREY
A
EXTERNAL SENSOR
INTERNAL SENSOR
Once the communication bus has been correctly wired, the following settings must be carried out to activate the interlocking of two automations:
- menu ADV>INK:
It is necessary to distinguish between automation on the internal side and automation on the external side.
Select the INT item to indicate the automation on the internal side and the EXT item to indicate the automation on the external side
It is possible to associate the activation of a SIO1/SIO2 output to the interlock operation, for example to command a light signalling the status of the door:
- menu ADV>SIO1/SIO2:
select the SIGN item
- menu ADV>SIGN:
TS
OS-R
select the INK item
+24V
- 24V
TS
OS-L
The IO1/IO2 output will be activated when the door is locked due to the interlock (with this signal, for example, it will be possible to turn on the red light
+24V
- 24V
signal
TS
CS-E
to indicate that the passage is temporarily blocked)
OP-E
+24V
- 24V
It is possible to temporarily disable the interlock function via button/contact:
TS
CS-I
OP-I
+24V
USB
- menu ADV>SIO1/SIO2/SI3:
- 24V
select the INKE (Interlock Exclusion) item
Closing the IO1/IO2/I3 output on -24V will disable the interlock function.
13.3.1 Interlock operation
The interlocked automations will open one at a time, waiting until the other automation is closed before opening.
NOTE: It is important to establish the correct direction of travel by indicating the internal and external automation, then correctly setting the internal and
external radar as these choices affect the interlock's operating logic.
Starting from the rest state, in which both automations are closed, the first to receive an open command starts the opening manoeuvre.
The other automation, on the other hand, goes into the 'locked' state where it does not accept any opening commands from the OP-I OP-E contacts.
It is however possible to open (for safety reasons etc) using the KO priority open command.
INTERNAL DOOR - INT
S
TS
+24V
OS-R
+24V
- 24V
- 24V
L
TS
H
OS-L
+24V
+24V
- 24V
- 24V
TS
PINK
CS-E
OP-E
+24V
- 24V
PP
RED
TS
CS-I
YELLOW
OP-I
BROWN + WHITE
+24V
USB
- 24V
GREEN+BLUE
B
S
TS
KO
+24V
OS-R
IO2
+24V
- 24V
IO1
- 24V
+24V
L
- 24V
TS
H
OS-L
+24V
+24V
- 24V
- 24V
TS
CS-E
OP-E
+24V
- 24V
PP
ENTER
TS
CS-I
OP-I
+24V
ESC
- 24V
indoor
ENVIRONMENT
Internal radar (OP-I)
Interior door (EXT)
KO
IO2
IO1
+24V
- 24V
ENTER
ESC
A
EXTERNAL SENSOR
S
KO
+24V
IO2
- 24V
IO1
+24V
L
- 24V
H
+24V
- 24V
PP
ENTER
USB
ESC
Internal radar (OP-I)
Exterior radar (OP-E)
21
RED
YELLOW
BROWN + WHITE
GREEN+BLUE
RED
PINK
YELLOW
BROWN+GREY+WHITE
GREEN+BLUE
GREY
PINK
B
INTERNAL SENSOR
S
TS
KO
OS-R
+24V
IO2
+24V
- 24V
IO1
- 24V
+24V
L
- 24V
TS
H
OS-L
+24V
+24V
- 24V
- 24V
TS
CS-E
OP-E
+24V
- 24V
PP
ENTER
TS
CS-I
OP-I
+24V
USB
- 24V
ESC
outdoor
ENVIRONMENT
Exterior radar (OP-E)
Exterior door (EXT)
EXTERNAL DOOR - EXT
S
TS
KO
+24V
OS-R
IO2
+24V
- 24V
IO1
- 24V
+24V
L
- 24V
TS
H
OS-L
+24V
+24V
- 24V
- 24V
TS
CS-E
OP-E
+24V
- 24V
PP
ENTER
TS
CS-I
OP-I
+24V
USB
- 24V
ESC
S
TS
KO
OS-R
+24V
IO2
+24V
- 24V
IO1
- 24V
+24V
L
- 24V
TS
H
OS-L
+24V
+24V
- 24V
- 24V
TS
CS-E
OP-E
+24V
- 24V
PP
ENTER
TS
CS-I
OP-I
+24V
USB
- 24V
ESC

Publicidad

loading