12
Menu
The SLIDER 2.0 control unit is equipped with 5 buttons and 4 alphanumerical displays to set all the necessary adjustments.
Operation of the 4 buttons is indicated in the table
Buttons
Description
PP (OP)
OPEN button carries out the OPEN command equivalent to KO contact.
ENTER
Selection button, each time it is pressed you enter the selected parameter.
Saving button by pressing for 1 second you "SAVE" the selected value.
ESC
Escape button, each time it is pressed you exit the selected parameter or from the menu.
h
Scroll button, each time it is pressed, you select a menu item or increase the value of the
selected item.
i
Scroll button, each time it is pressed, you select a menu item or reduce the value of the
selected item
11.1 MENUS LIST
- -ON-
basic parameters
- INFO
board information
- MEM
memory management
- ADV
advanced parameters
- SEL
selector
11.2 MENU -ON-
ID
Description
OPEN
Opening direction selection
VOP
Opening speed
VCL
Closure speed
TAC
Automatic closure time
PUSH
Automation thrust force
PART
Percentage of partial opening
BTMD
Battery operating mode
RAMP
Acceleration time
11.3 INFO MENU
ID
Description
VER
Fw version
CYCL
Number of executed manoeuvres
SERV
Maintenance signalling setting
LOG
Saving the board log
push ENTER to enter the ON menu
push h or i to enter other menus
Values
<> −>
<−
100 - 800
100 - 800
NO
1 - 30
1 - 10
10 - 90
NO
NOPN
OPEN
UNLK
CONT
EMER
100 - 2000
Valeurs
XXXX
0 - 9999
NO
1 - 9999
NO/YES
*(NOMS)
15
TS
OS-R
+24V
- 24V
TS
OS-L
+24V
- 24V
TS
CS-E
OP-E
+24V
- 24V
TS
CS-I
OP-I
+24V
- 24V
Notes
Double door / single door opening to the right
Single door opening to the left
[mm/s]
[mm/s]
NO = automatic closure disabled
[s]
1 = min, 10 = max
[%]
Battery not considered
In case of power failure, if the operating mode is in night mode, an
opening is performed. If the operating mode is in daytime mode,
it behaves as in continuous operation.
In the event of a power failure, the door also opens in night stop
mode
The unlock device uncouples and the door does not move
The door continues to operate normally, with low battery the door
remains in open position.
In case of a power failure, the door opens and remains open.
100 = Maximum acceleration [ms]
Notes
XXXX = firmware version
Number of executed manoeuvres in thousands: 1 = 1000
manoeuvres
NO = signalling disabled
Number of manoeuvres after which the maintenance warning is
signalled on the display of the control unit (in thousands) or setting
SIO1/SIO2 signal
Select YES and press ENTER until the writing SAVE appears.
The log file (text file) will be saved in
-ON-DS/SLIDING/LOG/
*If NOMS appears, the USB pen is not detected or is absent
S
KO
+24V
IO2
- 24V
IO1
+24V
L
- 24V
H
+24V
- 24V
PP
ENTER
USB
ESC
-
+
LK
J2