Descargar Imprimir esta página

RIB SLIDER 2.0 Manual página 54

Publicidad

Idiomas disponibles

Idiomas disponibles

13
Start-up procedure for automatic sliding doors
13.1 Preliminary checks
At the end of the installation activities, move the doors manually and check that the movement is regular and without friction.
Check the structure robustness and the correct fastening of all the screws.
Check that electrical connections have been carried out correctly.
N.B. For doors with emergency exits with one leaf and left opening, the carriage must be fastened to the upper part of the belt, as indicated in the figure.
13.2 Before connecting possible safety devices, leave the jumpers on the safety terminal boards of the electronic control TS-CS-I, TS-CS-E, TS-OS-L, TS-OS-R).
N.B. The first opening and closing manoeuvre is carried out with low speed to enable automatic detection of the stop measurements
13.3 To ensure that the electronic control has the factory settings, restore the values using the menu:
MEM > FSET > YES (confirm by pressing ENTER for 1 second).
13.4 Carry out menu adjustments as indicated in chapter 9. Use the OPEN button to give the opening commands and check that the door is working properly.
N.B. The automation automatically recognises possible obstacles during the closing (movement inversion) and opening manoeuvre (movement stops).
13.5 Connect the command and safety devices one at a time to protect the door closing manoeuvre, as indicated in chapter 8.5 and check its correct
operation.
N.B. Check that the passage compartment is correctly protected by safety sensors, in compliance with the provisions of the European standard EN16005 (Annex
C).
13.6 Connect the safety devices one at a time to protect the door opening manoeuvre, as indicated in chapter 8.6 and check its correct operation.
N.B. In case the distances between the door and the fixed parts comply with the European standard EN16005 (chapter 4.6.2.1.a), safety sensors in opening
are not necessary (X ≤ 100 and Y ≥ 200).
13.7 Connect the functions selector as indicated in chapter 9.4.
13.8 When start-up is complete, deliver the instruction manual to the manager of the automatic door, including the warnings and information necessary to
maintain safety and functionality of the automatic door.
N.B. The manufacturer of the automatic sliding door must add its identification label of the system.
14
Faults search
Other than the following list of possible problems, the warnings shown on the display are available, as indicated in chapter 12.1.
Problem
The automation does not open or
close.
The automation does not carry out the
functions set.
Movement of the doors is not linear or
movement is inverted for no reason.
The automation opens but does not
close.
Safety devices do not intervene.
The automation opens by itself.
Possible cause
No mains power supply (display off).
Short-circuit of external accessories
The door is locked with latches or locks.
Functions selector with wrong setting.
Command or safety devices are always activated.
Automation did not correctly detect the stop
measurements.
The safety devices test causes anomalies.
The opening devices are activated.
Automatic closure is not working.
Wrong connections between the safety devices and
electronic control.
The opening and safety devices are unstable or
detect bodies in motion.
Intervention
Check the presence of the mains power supply.
Disconnect all the accessories from the terminals
-24V/+24V and reconnect them one at a time (check the
presence of 24V voltage).
Check that the doors move freely.
Check and correct the functions selector settings.
Disconnect the devices from the terminal boards and
check the door's operation.
Reset by first switching off the automation then
switching it on.
Bridge one contact at a time TS/OS-R, TS/OS-L, TS/CS-E,
TS/CS-I.
Check that the opening sensors are not subject to
vibrations, do not make false detections or the presence
of objects in motion in the action range.
Check the settings of the functions selector.
Check that the safety contacts of the devices are
correctly connected to the terminal boards and the
relevant jumpers were removed.
Check that the opening sensors are not subject to
vibrations, do not make false detections or the presence
of bodies in motion in the action range.
22