A. Control Panel
NOTE: Total power drawn from all receptacles must not exceed
the nameplate ratings.
B.
SCHUKO Receptacle
16 amps of current may be drawn from the receptacle.
It is limited by the circuit protector size.
C.
Circuit Protectors
The receptacles are protected by an AC circuit protector. If the
generator is overloaded or an external short circuit occurs, the circuit
protector will trip. If this occurs, disconnect all electrical loads and
try to determine the cause of the problem before attempting to use the
generator again. If overloading causes the circuit protector to trip,
reduce the load. NOTE: Continuous tripping of the circuit
protector may cause damage to generator or equipment. The
circuit protector may be reset by pushing the button of the protector.
D. Ground Terminal
E. Engine On/Off Switch
F.
208 CC OHV Engine
L
E
H
K
English
English
GENERATOR FEATURES
GENERATOR FEATURES
.
M
O
N
B
C
G
F
G. Recoil Starter
H. Engine Choke Lever
I. Oil Filler Cap
J. Oil Drain Plug
K. Air Filter
L.
Fuel Tank
Maximum diameter allowable of the tank 300mm.
M. Fuel Shut-Off Valve
Valve is on the fuel tank (not supplied with generator).
N. Fuel Regulator (under shroud)
O. Multimeter
• When the generator is started, the voltage value is shown first.
• Press and release the mode button to toggle between Voltage,
Frequency, Total Hour Meter and Timer.
• Voltage (V) displays the operating voltage of the generator.
•
Frequency (F) displays the frequency in hertz at which the
generator is running.
• The Timer displays the time in hours and minutes each time
the generator is ran. The run timer resets to 00:00 when the
generator is shut off.
A
D
12
14
I
J