Descargar Imprimir esta página

Angelo Po 0S0FR3E Manual De Uso página 151

Freidora eléctrica

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

FAULTS
CONVERTING THE POWER SUPPLY (1S0FR3E - 1S1FR4E)
NOTE: The appliance is supplied at an
operating voltage of 400V/3N (indicated on
the sticker applied to the nameplate); the
conversion to 230V3~ can be carried out as
described below.
HAZARD: Before doing any work, turn
off the general power supply.
Pull off the knobs (A).
1)
400V3N
230V3
Remove the test voltage sticker from the
6)
nameplate and apply the new one to high-
light the voltage being used.
NOTE: After completing the opera-
tion, check for any faults.
3413910_inst_GB_rev.1
Undo the screws (B) to remove the control
2)
panel (C).
Modify the connections to the heating ele-
3)
ment terminals (D) as shown in the wiring dia-
gram at the end of the manual.
Fit the jumper (E) to make the electrical con-
4)
nection (F- G).
After completing the operation, fi t everything
5)
back in place.
A
D
G
D
B
B
C
E
F
ENGLISH
13

Publicidad

loading

Este manual también es adecuado para:

1s0fr4e0s1fr3e1s1fr4e