Removing the
cover plate
66
(4)
(3)
(1) (2)
(3)
(4)
(5) (6)
7
8
(5)
9
10
11
1
2
NOTE! There will still be some
grinding fluid in the tank. Only the
grinding fluid from the device
housing was removed using the
drain hose
Pull the key (4) for fixing the tank out
towards the front
Pull the tank (3) down and out of the
housing
Empty the tank completely and clean it
Clean and check the tank seal (5)
Replace the tank and fix it in place with
the key
The key must engage audibly
Put the drain hose back in the collec-
ting cup
NOTE! Before removing the cover
plate, make sure that there is no
more grinding fluid in the housing.
Remove the Allen screws (1) - (6) on
the cover plate using a 2.5 mm Allen
key
Take off the cover plate and the vie-
wing window