GAS CONVERSIONS
Gas Connection to Natural Gas
5. Use an adjustable wrench to remove the LP gas pressure
regulator/hose
assembly from the 90 ° brass adapter.
Explosion Hazard
Use a new CSA international
approved
"outdoor"
gas supply
line.
Securely tighten
all gas connections.
Failure to do so can result in death, explosion,
or fire.
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1 - latest edition, or
CAN/CGA-B149.1
Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch
Park
Quincy, Massachusetts
02269
IMPORTANT: The Natural gas Conversion
Kit supplied with this
grill must be used.
1. Turn off all burner control valves.
2. Turn off the main gas supply valve.
3. Disconnect
20 Ib LP gas fuel tank (if present) and remove the
20 Ib LP gas fuel tank from the grill cabinet.
4. Use a Phillips screwdriver to remove the 2-piece 90 ° brass
clamp mounting bracket from the cabinet wall.
/
/
A. Flexible gas hose from grill
B. 90 ° brass adapter
C. LP gas pressure regulator/hose
assembly
B
6. Install the Natural gas pressure regulator onto the flexible gas
hose from the grill.
7. Check that the Natural gas pressure regulator is positioned
under the grill (as shown in the following illustration) and is
not pinched or kinked.
8. Use 4 screws to attach the Natural gas pressure regulator to
the back of the enclosure.
A
\
B
A. Natural gas pressure regulator
B. Four %_" x 10 mm truss head screws
A
A. 4 screws
B. 2-piece 90 ° brass clamp mounting bracket
B
Make gas connections.
A combination
of pipe fittings must be used to connect the
grill to the existing gas line.
The 10 ft (3.0 m) PVC flexible gas supply hose design-
certified by CSA must be used.
Pipe-joint compounds
suitable for use with Natural gas
must be used. Do not use Teflon ®ttape.
Connect the brass connector on one end of the 10 ft (3.0 m)
PVC flexible gas supply hose (supplied) to the Natural gas
pressure regulator (A).
1-®TEFLON is a registered trademark
of E.I. Du Pont De Nemours and Company.
12

Publicidad

loading