Power Switch - Bosch GTS1041A Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

tool has activated 25 times. Also, this light will
flash when service is recommended.
For additional information and Troubleshooting
see page 45.
CUTTING ELECTRICALLY
CONDUCTIVE MATERIALS
The Active Response Technology™ injury mitiga-
tion system monitors for change in the detection
plate signal caused by operator contacting the
blade. Some materials such as aluminum ve-
neered plywood may mimic this effect.
Any metal, metal foil composite, or wet lumber
will cause the system to react if cut.
Allow the pressure treated
materials to air dry before
cutting in normal mode. Pressure treated lum-
ber is treated with chemicals that are electrically
conductive when wet.

POWER SWITCH

NOTE: This table saw has two safety features
that helps prevent accidental starting. The switch
can be locked in the off position, see "To prevent
unauthorized use" below. Also, the Active Re-
sponse Technology™ system prevents the motor
from restarting if the switch is on when the plug is
connected to a power source.
To turn saw on: lift switch lever by pinching side
walls and lifting, or reach under the switch and
pull up. This action starts the saw (Fig. 37)
To turn off power: push switch lever down to its
original position (Fig. 36).
To prevent unauthorized use, the switch can
accommodate a padlock with a 3/16" or 1/4" di-
ameter shackle (not provided with table saw),
(Fig. 36).
BYPASS SWITCH
Use bypass mode only
when cutting electrically
conductive materials. Using bypass mode
when not needed eliminates protection provided
by Active Response Technology™.
If a conductive material needs to be cut, the tool
has a bypass switch which disarms the Active
Response Technology™ injury mitigation system.
Press and hold the bypass switch A with one
hand, then turn on the power switch B with the
other. The saw blade will start to spin. The in-
formation panel will change from Green to Yellow
(Fig. 37).
1600A009XC 09-15.indb 26
Fig. 37
A
When the power switch is turned off, the bypass
mode will be deactivated. Then the indicator will
change from Yellow to Green. The Active Re-
sponse Technology™ will be active for the next
cut unless the bypass switch is pressed again.
To prevent unauthorized system bypass, the
switch can accommodate a padlock with a 3/16"
or 1/4" diameter padlock (not provided with table
saw), (Fig. 36).
NEAR FIELD COMMUNICATION (NFC)
INTERFACE
The Active Response Technology™ injury miti-
gation system can interface with smart phones
that have NFC functionality and the Bosch Power
Tools app installed.
Do not use the NFC func-
tion while the saw blade is
spinning. Distraction while cutting may result in
tool damage and serious personal injury.
To connect to the NFC, launch the Bosch Toolbox
App and click the "Connect to tool" button. Place
the smart phone against the Near Field Com-
munication interface. The system will send all the
current data to phone.
The operator can use this to get maintenance
recommendations, reset procedures or trouble-
shooting procedures. You can also use this sys-
tem to register the tool with Bosch. In case the
tool is stolen, this registration cannot be obscured
by defacing the nameplate.
26
ON
B
9/14/15 1:51 PM

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido