Theodolite
Illumination
Compensator only for DGT 2
Compensation range, vertikal
Resolution
Compensation accuracy
Optical Plummet
Magnification
Field of view
Focussing range
Bubble Vials
Plate level
Circular bubble vial
Working range
Voltage
Batteries
Battery life
Operating temperature
Dimensions
Weight according to EPTA-Procedure 01/2003
Degree of protection
Assembly
Inserting/Replacing the Batteries
(see figures A1 – A3)
Alkali-manganese batteries are recommended for the measur-
ing tool.
– Press latch 22 down and remove the battery lid 23 upward.
– Press hook 24 down to disengage the snap lock and open the
battery compartment 15.
– Insert the batteries into the battery compartment according
to the representation.
– Always replace all batteries at the same time. Only use bat-
teries from one brand and with the identical capacity.
– Close the battery compartment and press hook 24 down-
ward until it engages.
– Close the battery lid 23.
 Remove the batteries from the measuring tool when not
using it for extended periods. When storing for extended
periods, the batteries can corrode and self-discharge.
Charge-control Indicator
– Replace the batteries as soon as the battery indica-
tion aside appears.
Mounting the Tribrach (see figures B1–B2)
– To mount the tribrach, position the measuring tool so that
screw casing 26 engages into the recess of the tribrach.
Afterwards, turn thumbscrew 11 180° in clockwise direc-
tion to lock the measuring tool.
– To remove the tribrach, turn the thumbscrew 11 180° in
anticlockwise direction and remove the measuring tool.
1 609 92A 0LD • 23.10.14
DGT 10
Display + eyepiece
4 x
0.5 m–infinite
30''/2 mm
8'/2 mm
4–6 DC
4 x 1.5 VLR6 (AA)
15 h
–20 ... +50 °C
145 x 200 x 300 mm
4.4 kg
IP 54 (dust and splash water
protected)
Note: only for DGT 2:
Tribrachs with laser plummet are available as optional accesso-
ries for the DGT 2.
Operation
Starting Operation of the Display
Switching On the Display
– To switch on the display, press the On/Off button 20.
All symbols light up on the display 3 for 2 seconds.
(see figure C1)
– The standard indication is shown on the display.
(see figure C2)
Switching Off the Display
– To switch off the display, press the On/Off button 20 again.
 When storing or transporting, always switch the display
off.
Display + eyepiece
0.5 m–infinite
4 x 1.5 VLR6 (AA)
–20 ... +50 °C
145 x 200 x 300 mm
IP 54 (dust and splash water
DGT 2
± 3 min
1 s
< ± 5 s
4 x
30''/2 mm
8'/2 mm
4–6 DC
15 h
4.8 kg
protected)
English | 19