Configuration
6.2
Menu level 1: Set temperature
The system always starts with a defined value for the room temperature.
This parameter can be configured between 17 and 30 °C:
➤ Start configuration mode (see chapter "Starting and ending configura-
tion mode" on page 43).
✓ The first digit of the display (fig. 18, 9) shows the menu level and the
second and third show the parameter which can be set.
➤ Press the Mode + button (fig. 18, 8) to change the parameter.
➤ Use the Temp. + and - buttons (fig. 18, 4 and 5) to select the tempera-
ture (in °C) for starting the system.
✓ The digits in the display flash until the parameter you enter is confirmed.
➤ Press the Mode + button (fig. 18, 8) to confirm your entry.
✓ The set value is saved and is then used when the system is restarted.
✓ You are now in menu level 1 and can use the Temp. + and - buttons
(fig. 18, 4 and 5) to switch between menu levels.
6.3
Menu level 2: Low voltage cut-off
The battery monitor protects the battery from excessive discharging.
When the battery monitor switches the device off, the battery only has part of
its charging capacity. In this case, avoid starting repeatedly or operating
electrical consumers. Make sure that the battery is recharged. As soon as
the required voltage is available again, the system can be operated again.
If only the set power supply is available here for the air conditioner, the
system is switched off.
➤ Start configuration mode (see chapter "Starting and ending configura-
tion mode" on page 43).
✓ The first digit of the display (fig. 18, 9) shows the menu level and the
second and third show the parameter which can be set.
➤ Press the Temp. + button (fig. 18, 4) once to switch to menu level 2.
➤ Press the Mode + button (fig. 18, 8) to change the parameter.
✓ The digits in the display flash until the parameter you enter is confirmed.