Descargar Imprimir esta página

Dometic WAECO CoolAir SP-900 Instrucciones De Instalación página 45

Equipo de aire acondicionado split para camiones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
SP-900-Install.book Seite 45 Montag, 25. Januar 2010 4:53 16
CoolAir
➤ Use the Temp. + and - buttons (fig. 184 or 5) to select the low voltage
➤ Press the Mode + button (fig. 18, 8) to confirm your entry.
✓ The set value is saved and is then used when the system is restarted.
✓ You are now in menu level 2 and can use the Temp. + and - buttons
6.4
Menu level 3: Operating mode
The system always starts with a defined operating mode. This parameter
can be configured:
➤ Start configuration mode (see chapter "Starting and ending configura-
✓ The first digit of the display (fig. 18, 9) shows the menu level and the
➤ Press the Temp. + button (fig. 18, 3) twice to switch to menu level 3.
➤ Press the Mode + button (fig. 18, 8) to change the parameter.
✓ The digits in the display flash until the parameter you enter is confirmed.
➤ Use the Temp. + and - buttons (fig. 18, 4 and 5) to select the mode for
➤ Press the Mode + button (fig. 18, 8) to confirm your entry.
✓ The set value is saved and is then used when the system is restarted.
✓ You are now in menu level 3 and can use the Temp. + and - buttons
cut-off value. The characteristic figures at second and third place on
the digital display represent the voltage (V) at which the system is shut
down:
Charac-
Low voltage
teristic
shutdown
figure
23.2
01
23.3
02
23.4
03
23.5
04
23.6
05
(fig. 18, 4 and 5) to switch between menu levels.
tion mode" on page 43).
second and third show the parameter which can be set.
starting the system:
Characteristic
Operating mode
figure
00
01
02
03
(fig. 18, 4 and 5) to switch between menu levels.
Configuration
Charac-
Low voltage
teristic
shutdown
figure
06
07
08
09
10
Automatic mode
Operating mode 1
Operating mode 2
Operating mode 3
23.7
23.8
23.9
24.0
24.1
45

Publicidad

loading