3 Technical description
3.4
20
(A)
max. 250 m
CANopen
(3)
(A)
(2)
(A) Terminated connection
(C) Non-terminated connection
(D) Non-terminated connection
(X) Conergy or Voltwerk monitoring unit
(1) CAN distributor
(2) CAN distributor
(3) CAN distributor
A CAN distributor (1) plays a central role in the CAN connection to the two
CAN distributors (2) and (3). The data exchange between the two CAN
distributors (2) and (3) and the monitoring unit always takes place via the
CAN distributor (1). If the CAN distributor (1) has a fault, it cannot receive
or transfer data. In this case, the monitoring unit also cannot monitor the
two other CAN distributors (2) and (3).
Optional component power supply
If you are using Conergy or Voltwerk 2-axis tracking systems, in addition to
the CAN distributor, a power supply (see Fig. 3.1, page 13, item (9)) is
also required. The power supply supplies the motor control systems with
the necessary auxiliary voltage.
(D)
(A)
(C)
(1)
SmartConnect
Operating manual
(X)
SmartControl