Io-Link Smart Sensor Profile Ed. 2 (Bml Sl1-Alz1-Ue/Mzz-_U1L; Communication Parameters - Balluff BML SL1-ALZ-ZZ Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
7
IO-Link Smart Sensor profile Ed. 2 (BML SL1-ALZ1-UE/MZZ-_U1L-...)
7.1

Communication parameters

An introduction to the IO-Link interface can be
found in the document Interfaces for
Magnetically Coded Position Measuring System
BML.
In Tab. 7-1 the basic IO-Link specification for the BML SL1
is described.
Specification
Transfer rate
Minimum cycle time of device
Frame specification:
Amount of preoperate data required
Amount of operate data required
ISDU
IO-Link protocol version
Amount of process data from the device to the master
Amount of process data from the master to the device
Manufacturer ID
Device identifier
IO-Link profile
IO-Link profile type
Switching signal in SIO Mode
Tab. 7-1:
Device specification BML
The minimal cycle time (MinCycleTime) of the
BML is 1 ms.
The master can when needed increase the
cycle time, which is why the actual cycle time
used (MasterCycleTime) depends on the
master.
24
english
IO-Link Description
COM3
MinCycleTime
M-Sequence Capability:
M-Sequence Type Preoperate
M-Sequence Type Operate
ISDU supported
Revision ID
ProcessDataIn
ProcessDataOut
Vendor ID
Device ID
Profile
Profile Type
SIO
Value
230.4 kBaud
1 ms (0x0A)
0×1B
2 bytes
2 bytes
Supported
0x11 (Version 1.1)
6 bytes (0xC5)
0 bytes (0x00)
0x0378
0x030A0x (BML SL1-
ALZ1-UMZZ-_U1L-...)
0x030A0y (BML SL1-
ALZ1-UEZZ-_U1L-...)
Smart Sensor Profile Ed 2
(Digital Measuring Sensor)
SSP 3.2
OUT1, OUT2

Publicidad

Tabla de contenido
loading

Tabla de contenido