NOTE: When set schedule duration, priorities for SPEEDS are follows: SPEED 1 -> SPEED 2 ->
SPEED 3 -> SPEED 4.
Example:
Starting Schedule (Before Adjustment)
SPEED 1 duration = 18 hours
SPEED 2 duration = 2 hours
SPEED 3 duration = 2 hours
SPEED 4 duration = 2 hours
If the user reprograms SPEED 1 to run for 22 hours, SPEED 2 (lower priority speed) will auto-
matically adjust to a 1 hour duration and SPEED 4 (lowest priority speed) will adjust to a 0 hour
duration. End Schedule (After Adjustment)
SPEED 1 duration = 22 hours
SPEED 2 duration = 1 hour
SPEED 3 duration = 1 hours
SPEED 4 duration = 0 hours
NOTE: The total program duration is always shorter than 24 hours.
MAINTENANCE
Freeze Protection Program
This pump comes equipped with an automatic freeze protection circuit that will power the
pump on if surrounding air reaches the freeze protection temperature setting. The circuit pro-
vides continual, moderate flow through plumbing to protect pool equipment.
This feature is enabled by default. To enable Freeze Protection:
• Ensure the pump is in STOP mode by cycling the START/STOP button until the red LED above
it is not lit.
• Press and hold the ^ and v arrows simultaneously to enter the freeze protection settings.
• While in this menu, use the < and > arrows to cycle between options.
• The default freeze protection speed is 1000 RPM. Use the ^ and v arrows to set this to your
desired speed between 750-3450 RPM.
• Next, use the + and - arrows to set the duration in hours the pump runs once freeze protec-
tion is triggered.
• Set duration to 0 to deactivate freeze protection.
• Lastly, use the + and - arrows to set the activation temperature between 4.4°C and 10°C.
• The MODE SELECT button will cycle between Fahrenheit or Celsius.
The freeze protection minimum activation temperature is 4.4°C.due to the pump's proximity
to the warmer ground and its own latent/stored heat after running during the day. When the
pump sensor detects temperatures in this range, it is often already near or below freezing in
other areas of the pool equipment pad.