Routine maintenance
This pump requires little or no service,only routine maintenance needed is to keep the basket
clean, inspect basket once a week. When cleaning the basket, inspect o-ring or other damage
and replace it if necessary.
TROUBLESHOOTING
Error Code
The screen will display error codes once the pump encounter problems and stop running When
error codes occur, un-plug the pump power cord to shut down the pump, wait for the LED lights
to go out. Reconnect the power supply to the pump. Troubleshooting is required if the error
code appear again. Details error code and troubleshooting description list in below table.
Error Code
E-01
Inverter unit protection
E-02
Acceleration over current E-12
E-03
Deceleration over current E-14
E-04
Constant speed over
current
E-05
Acceleration over voltage E-17
E-06
Deceleration over voltage E-24
E-07
Constant speed over
voltage
E-08
Under voltage fault
E-09
Motor overload
E-10
Inverter overload
E-08:
Absolute AC low voltage is detected. This may be caused by normal voltage changes and will
clear itself. Use a multimeter to check whether the input voltage is lower than 220v. If the in-
put voltage is lower than 220v, there is a problem with the supply voltage. If the input voltage
is correct, there may be a problem with the controller.
• Turn off power and release pressure from the sys-
tem.
• Inspect the pump basket for debris and remove it.
Replace the basket if it is cracked.
• Lose the suction inlet hose or piping.
• Turn the transparent Lid nut anti clockwise to re-
lease by hand and lift the transparent Lid up.
• Remove the basket back and fill the pump pot and
volute up to the inlet port with water.
• Clean the clear lid, o-ring, and sealing surface of
the pump of any debris.
• Verify that all valves have been returned to the
proper position for normal operation.
• Turn ON the power to the pump.
Description
E-11
E-16
16
Error Code
Phase loss at input side
Phase failure at output side
Module overheating
Communication fault
Current detection fault
Inverter hardware fault