Figure 27. Menu of the automatic test mode
7. DIAGNOSTICS OF 48 V BELT STARTER GENERATORS
In the alternator diagnostic mode for 48 V alternators (see Figure 28), the following distinctive
information may be displayed on the screen:
1 - Measured alternator speed by the control unit.
2 - Current resistance or torque, which is set by buttons at position 5.
3 - Activation of testing in starter mode.
4 - Activation of testing in alternator mode.
5 - Selection of resistance moment (in alternator mode) or torque moment (in starter mode).
6 - Stop the testing process.
The sequence of operations is as follows:
1. Fix the alternator on the bench, connect the power leads. Use special cable MS-334xx to connect
to the socket.
2. Go to the "Alternator" menu, and then enter the diagnostic mode for 48 V alternators.
3. Before activating the diagnostic mode, a preliminary alternator check window will appear, see
Figure 26.
33